X-ray and finite element analysis of deformation response of closed-cell metal foam subjected to compressive loading

  1. 1.
    0388997 - ÚTAM 2013 RIV GB eng J - Článek v odborném periodiku
    Jiroušek, Ondřej - Doktor, Tomáš - Kytýř, Daniel - Zlámal, Petr - Fíla, Tomáš - Koudelka_ml., Petr - Jandejsek, Ivan - Vavřík, Daniel
    X-ray and finite element analysis of deformation response of closed-cell metal foam subjected to compressive loading.
    Journal of Instrumentation. Roč. 8, č. 2 (2013), s. 2012-2016. ISSN 1748-0221. E-ISSN 1748-0221
    Grant CEP: GA ČR GAP105/12/0824
    Institucionální podpora: RVO:68378297
    Klíčová slova: X-ray radiography and digital radiography * computerized tomography and computed radiography * pixelated detectors and associated VLSI electronics
    Kód oboru RIV: JG - Hutnictví, kovové materiály
    Impakt faktor: 1.526, rok: 2013
    http://iopscience.iop.org/1748-0221/8/02/C02012

    Time-lapse X-ray computed microtomography was employed to quantify the deformation behaviour of closed-cell aluminium foam. The specimen was incrementally loaded and tomographically scanned using a custom X-ray tomographic device to capture the deforming microstructure. Because of the very small thickness of the cell walls and the high ratio between pore size and cell wall thickness cone-beam reconstruction procedure was applied. A finite element (FE) model was developed based on the reconstructed three-dimensional data. The FE model was used for two purposes: i) the nodal points were used for tracking the displacements of the deforming structure, ii) verification of the material model for description of the foam's deformational behaviour.