Počet záznamů: 1  

Inconsistencies of neutron flux parameters for k(0) standardization in neutron activation analysis determined with the use of Au+Zr and Au+Mo+Cr monitor sets at the LVR-15 reactor in Rez

  1. 1.
    0384333 - ÚJF 2013 RIV HU eng J - Článek v odborném periodiku
    Kubešová, Marie - Kučera, Jan
    Inconsistencies of neutron flux parameters for k(0) standardization in neutron activation analysis determined with the use of Au+Zr and Au+Mo+Cr monitor sets at the LVR-15 reactor in Rez.
    Journal of Radioanalytical and Nuclear Chemistry. Roč. 293, č. 2 (2012), s. 665-674. ISSN 0236-5731. E-ISSN 1588-2780
    Grant CEP: GA ČR GA202/09/0363
    Institucionální podpora: RVO:61389005
    Klíčová slova: Neutron activation analysis * K(0) standardization * Neutron flux parameters
    Kód oboru RIV: BG - Jaderná, atomová a mol. fyzika, urychlovače
    Impakt faktor: 1.467, rok: 2012

    Multipurpose research reactors require monitoring of neutron flux parameters (alpha, f, F (c) or I broken vertical bar (th) ) during every irradiation of samples when k(0) standardization in neutron activation analysis is to be used, because the above parameters may change quite frequently and unpredictably. We tested two monitor sets consisting of Au+Zr and Au+Mo+Cr for determination of the neutron flux parameters in k(0)-NAA at the LVR-15 reactor in A similar to eA3/4. Based on analysis of several reference materials, we found the use of the Au+Zr monitor set superior over the Au+Mo+Cr monitor set in the specific conditions of the LVR-15 reactor.