Počet záznamů: 1  

Precise strain measurement in complex materials using Digital Volumetric Correlation and time lapse micro-CT data

  1. 1.
    0368259 - ÚTAM 2012 RIV GB eng O - Ostatní výsledky
    Jandejsek, Ivan - Vavřík, Daniel - Jiroušek, Ondřej
    Precise strain measurement in complex materials using Digital Volumetric Correlation and time lapse micro-CT data.
    Procedia Engineering. Elsevier, 2011 - (Mario Guagliano; Laura Vergani). s. 1730-1735. ISSN 1877-7058
    Grant CEP: GA ČR(CZ) GA103/09/2101; GA ČR(CZ) GAP105/10/2305
    Výzkumný záměr: CEZ:AV0Z20710524
    Klíčová slova: digital volumetric correlation * strain measurement * trabecular bone
    Kód oboru RIV: JJ - Ostatní materiály

    Digital volumetric correlation (DVC) method is employed for evaluation of full-volume displacement and strain fields in deformed material with complex microstructure such as trabecular bone and metal foam. Volumetric image data was acquired using time lapse micro-CT. The displacement fields were measured in set of control points that were defined as tetrahedral FE mesh. The advantage of the approach is that the resulting strain can be directly compared to results of FE simulation of the experiment. Problems of accuracy, especially in evaluation of the strain field from the noisy measured displacements and problems of computational efficiency of the method are discussed.
    Trvalý link: http://hdl.handle.net/11104/0202653

     
     