Počet záznamů: 1
Characterization of electro-eroded surface of Ti alloys
- 1.0324218 - FGÚ 2009 RIV GB eng J - Článek v odborném periodiku
Starý, V. - Peřina, Vratislav - Bačáková, Lucie - Jirka, Ivan - Vorlíček, Vladimír - Fencl, J.
Characterization of electro-eroded surface of Ti alloys.
[Charakterizace elektroerodovaného povrchu titanových slitin.]
Journal of Physics: Conference Series. Roč. 100, - (2008), 012004-012004. ISSN 1742-6588. E-ISSN 1742-6596
Grant CEP: GA ČR(CZ) GA101/06/0226; GA AV ČR(CZ) KAN101120701
Výzkumný záměr: CEZ:AV0Z50110509; CEZ:AV0Z10480505; CEZ:AV0Z40400503; CEZ:AV0Z10100520
Klíčová slova: Ti alloys * surface properties * bone implants
Kód oboru RIV: JK - Koroze a povrchové úpravy materiálů
The roughness and chemical composition of the surface of electro-eroded Ti and the alloy Ti6Al4V, i.e. materials used for construction of artificial join replacements and other bone implants, were studied and compared with the parameters of an experimental material represented by the Ti5Al2.5Fe alloy. All samples had relatively highly rough surfaces (Ra about 12-10 um) and contained carbon in both amorphous and crystalline state. All surfaces supported the adhesion and growth of human osteoblast-like MG 63 cells in extent similar to that found on standard polystyrene cell culture dishes
Byla studována drsnost a chemické složení povrchu elektroerodovaného Ti a slitiny Ti6Al4V, tj. materiálů používaných pro konstrukci kloubních náhrad a dalších kostních implantátů, a tyto parametry byly porovnávány s odpovídajícími hodnotami získanými u experimentálního materiálu představovaného slitinou Ti5Al2.5Fe. Všechny vzorky mely relativně vysokou povrchovou drsnost (Ra kolem 12-10 um) a obashovaly amorfní i krystalický uhlík. Všechny povrchy podporovaly adhesi a růst lidských osteoblastům podobných buněk linie MG 63 v míře podobné jako na standardních kultivačních polystyrénových miskách
Trvalý link: http://hdl.handle.net/11104/0171970