Počet záznamů: 1  

Polyluminol based sensor for the detection of dissolved chlorine in water

  1. 1.
    0306583 - ÚFE 2008 IE eng A - Abstrakt
    Szili, M. - Kašík, Ivan - Matějec, Vlastimil - Kovács, B.
    Polyluminol based sensor for the detection of dissolved chlorine in water.
    [Sensor pro detekci chloru ve vodě na bázi polyluminolu.]
    EUROPTRODE IX. Book of Abstracts 9th European Conference on Optical Chemical Sensors and Biosensors. Dublin: Dublin City University, 2008. s. 108--. ISBN N.
    [EUROPTRODE /9./. 30.03.2008-02.04.2008, Dublin]
    Grant CEP: GA ČR(CZ) GA102/05/0948
    Výzkumný záměr: CEZ:AV0Z20670512
    Klíčová slova: fibre optic sensors * chlorine
    Kód oboru RIV: JB - Senzory, čidla, měření a regulace

    Chemoluminescent sensor for dissolved chlorine was prepared on electropolymerized luminol. Three different methods for polyluminol deposition were used and the resulting layers were tested. Highest CL intensities were recorded by using cyclic voltametry deposition technique. The resulting sensing layers showed a fast response (<5 s) and acceptable measuring ranges (0-20 and 30-800 μM) for chlorine determination.

    Byl vyvinut chemoluminiscentní sensor chloru založený na elektropolymerní formě luminolu. Polyluminol byl deponován třemi různými metodami a výsledné vrstvy byly charakterizovány. Nejintenzivnější luminiscenční odezvy byly získány z vrstev připravených cyklickou voltametrií. Připravené vrstvy vykazovaly rychlou odezvu (<5 s) v rozsahu (0-20 and 30-800 μM) přijatelném pro stanovení chloru.
    Trvalý link: http://hdl.handle.net/11104/0159565

     
     
Počet záznamů: 1  