Počet záznamů: 1
Compositional alteration of polyimide under high fluence implantation by Co+ and Fe+ ions
- 1.0185776 - UJF-V 20033095 RIV NL eng J - Článek v odborném periodiku
Popok, V. N. - Khaibullin, R. I. - Tóth, A. - Beshliu, V. - Hnatowicz, Vladimír - Macková, Anna
Compositional alteration of polyimide under high fluence implantation by Co+ and Fe+ ions.
Surface Science. Roč. 532, - (2003), s. 1034-1039. ISSN 0039-6028. E-ISSN 1879-2758
Grant CEP: GA ČR GA102/01/1324
Výzkumný záměr: CEZ:AV0Z1048901
Klíčová slova: ion implantation * radiation damage
Kód oboru RIV: BG - Jaderná, atomová a mol. fyzika, urychlovače
Impakt faktor: 2.063, rok: 2003
Polyimide(PI) foils were implanted with 40 keV Fe+ and Co+ ions to the fluences of 2.5 x 10(16)-1.25 x 10(17) cm(-2) at the ion current densities of 4, 8 and 12 muA cm(-2). Surface morphology and compositional alteration of the implanted polymer have been studied using atomic force microscopy, transmission electron microscopy, Rutherford backscattering and X-ray photoelectron spectroscopy. Carbonisation of the surface layer, followed by oxygen and nitrogen depletion is observed. These processes reach the saturation level at the applied high fluences. A further increase of ion fluence and density of ion current does not change the composition; only an increase in the metal concentration is observed. It is shown that metal ion implantation to high fluence at high ion current density can be effectively employed to form metal/polymer nanocomposites with required parameters.
Trvalý link: http://hdl.handle.net/11104/0082152
Počet záznamů: 1