    The behaviour of HPGe detectors operating at temperatures below 77 K.
    Nuclear Instruments & Methods in Physics Research Section A. Roč. 454, 2/3 (2000), s. 403-408. ISSN 0168-9002. E-ISSN 1872-9576
    Grant CEP: GA ČR GA202/99/0154; GA AV ČR KSK1048601
    Kód oboru RIV: BG - Jaderná, atomová a mol. fyzika, urychlovače
    Impakt faktor: 0.964, rok: 2000

    Planar detectors from high-purity germanium single crystalsdesigned for the detection of charged particles in low-temperature nuclear orientation experiments were tested in the temperature range 4.5-77 K. Various detector characteristics were measured. The distortions in spectra observed at thelowest temperatures are discussed. Good performance of the detectors in real experimental conditions was obtained.