Analytical Application of Silver Composite Electrode

  1. 1.
    0181375 - UFCH-W 20020034 RIV US eng J - Článek v odborném periodiku
    Navrátil, Tomáš - Kopanica, M.
    Analytical Application of Silver Composite Electrode.
    Critical Reviews in Analytical Chemistry. Roč. 32, č. 2 (2002), s. 153-166. ISSN 1040-8347. E-ISSN 1547-6510
    Grant CEP: GA ČR GA203/98/P239
    Výzkumný záměr: CEZ:AV0Z4040901
    Klíčová slova: silver composite electrode * voltammetry * halogenides
    Kód oboru RIV: CG - Elektrochemie
    Impakt faktor: 2.074, rok: 2002

    Silver composite electrode prepared from silver and graphite powder and methacrylate resin presents a suitable sensor for the voltammetric measurements. Their cathodic polarization enables the determination of nitrates, nitrites, organic nitro compounds and halide ions. DPASV enables the direct determination of lead in natural water samples without the elimination of the presence of SAS and of the dissolved oxygen. The effect of under potential deposition at the composite electrode differs was studied.