Mikuška, Pavel - Večeřa, Zbyněk
Effect of complexones and tensides on selectivity of nitrogen dioxide determination in air with a chemiluminescence aerosol detector.
Analytica Chimica Acta. Roč. 410, 1-2 (2000), s. 159-165. ISSN 0003-2670. E-ISSN 1873-4324
Grant CEP: GA ČR GA203/98/0943
Grant ostatní: COPERNICUS(BE) SUB-AERO EVK2-1999-000327
Kód oboru RIV: CB - Analytická chemie, separace
Impakt faktor: 1.849, rok: 2000
Modification of the luminol solution by means of addition of various complexones and surfactants has been investigated to eliminate interferences from gaseous co-pollutants in the determination of ambient nitrogen dioxide using a chemiluminescence aerosol detector. The simultaneous presence of EDTA and triton X-100 together with sulphite and iodide in the luminol solution suppressed interferences from ozone and peroxyacetyl nitrate to a negligible level and no scrubbers or corrections of the NO2 measurements were needed.