Počet záznamů: 1  

Use of X-ray computed tomography for construction of FE models of bones

  1. 1.
    0106139 - UTAM-F 20043041 CZ eng G - Konferenční sborník (zahraniční konf.)
    Jiroušek, Ondřej - Jírová, Jitka - Máca, J. - Zolotarev, I. (ed.) - Poživilová, A. (ed.)
    Use of X-ray computed tomography for construction of FE models of bones.
    Praha: Institute of Thermomechanics, Academy of Sciences of the Czech Republic, 2004. 8 s. ISBN 80-85918-88-9.
    [Engineering mechanics 2004. Svratka (CZ), 10.05.2004-13.05.2004]
    Výzkumný záměr: CEZ:AV0Z2071913
    Klíčová slova: finite element models, X-ray computed tomography, high-resolution models
    Kód oboru RIV: FI - Traumatologie, ortopedie

    The article reports on procedures used for development of FE models of bones on basis of data obtained from series of computed tomography (CT) scans. These models include mechanical properties reflecting the bone inhomogeneity through apparent density which can be easily retrieved from the CT scans. Experimental procedures used for evaluation of mechanical properties of cancellous bone using small samples of cylindrical shape were designed in such a way, which allows for determination of the viscoelastic properties of cancellous bone. Both compressive and tensile specimens are tested while for the strain measurement an optical method utilizing CCD camera of high resolution is used. Relationship between the apparent density and mechanical properties of cancellous bone in a power-law form is proposed.
    Trvalý link: http://hdl.handle.net/11104/0013322

     
     
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.