Počet záznamů: 1
Modeling of Trabecular Bone as Hierarchical Material Using Micro-CT Imaging and Nanoindentation
- 1.0089811 - ÚTAM 2011 RIV US eng A - Abstrakt
Jiroušek, Ondřej - Němeček, J.
Modeling of Trabecular Bone as Hierarchical Material Using Micro-CT Imaging and Nanoindentation.
[Modelování trabekulární kosti jako hierarchického materiálu pomocí mikroCT a nanoindentace.]
Ninth US National Congress on Computational Mechanics. Berkeley, CA: University of California, Berkeley, 2007 - (Hengst, R.). s. 62-62
[US National congress on Computational mechanics /9./. 22.07.2007-26.07.2007, San Francisco , California]
Grant CEP: GA ČR(CZ) GP103/07/P483
Výzkumný záměr: CEZ:AV0Z20710524
Klíčová slova: microfocus X-ray computed tomography * trabecular bone * nanoindentation * isotropic hardening plasticity
Kód oboru RIV: FI - Traumatologie, ortopedie
In this work microfocus X-ray computed tomography is used to reconstruct the structure of trabecular bone sample to develop a FEM model of high-resolution. Material properties used in the FEM model are obtained from nanoindentation experiments. Plasticity model with isotropic hardening is used with tissue yield stress set according to results from mechanical testing of cylindrical specimens.
V práci je ukázáno využití modelů trabekulární kosti získaných za použití dat z počítačové tomografie. Materiálové vlastnosti jsou stanoveny na základě nanoindentace. V MKP modelech je použito plasticity s izotropním zpevněním.
Trvalý link: http://hdl.handle.net/11104/0150899
Počet záznamů: 1