Počet záznamů: 1
High resolution neutron tomography with MEDIPIX-2
- 1.0029168 - ÚTAM 2006 RIV CH eng J - Článek v odborném periodiku
Jakůbek, J. - Holý, T. - Lehmann, E. - Pospíšil, S. - Uher, J. - Vacík, J. - Vavřík, Daniel - Vykydal, Z.
High resolution neutron tomography with MEDIPIX-2.
[Neutronová tomografie s vysokým rozlišením, používající MEDIPIX-2.]
PSI Scientific Report, 2004. III, - (2005), s. 221-221. ISSN 1423-7326
Výzkumný záměr: CEZ:AV0Z20710524
Klíčová slova: neutron tomography * neutron converter * neutron radiography
Kód oboru RIV: JB - Senzory, čidla, měření a regulace
http://num.web.psi.ch/reports/2004/ASQ/asq-2004-51.pdf
The properties of the neutron pixel detector based on the single X-ray photon pixel detector device Medipix-2 were investigated. Slow neutrons are captured and converted in a surface layer containing Li-6 to tritons and alpha particles which are subsequently detected by a silicon pixel detector. The imager was used for neutron tomographic measurements with high resolution.
Byly zkoumány vlastnosti pixelového detektoru neutronů, založeného na pixelovém detektoru jednotlivých X fotonů Medipix-2. Pomalé neutrony jsou zachycováy v povrchové vrstvě, obsahující Li-6, kde jsou konvertovány na tritony a alfa částice. Ty jsou následně detekovány křemíkovým pixelovým detektorem. Zobrazovací zařízení bylo použito na neutronovou tomografii s vysokým rozlišením.
Trvalý link: http://hdl.handle.net/11104/0119034
Počet záznamů: 1