Počet záznamů: 1  

Time-resolved Fourier transform infrared spectroscopy and updated system of neutral oxygen (O I) levels

  1. 1.
    SYSNO ASEP0499056
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevTime-resolved Fourier transform infrared spectroscopy and updated system of neutral oxygen (O I) levels
    Tvůrce(i) Civiš, Svatopluk (UFCH-W) RID, ORCID, SAI
    Kubelík, Petr (UFCH-W) RID, ORCID
    Ferus, Martin (UFCH-W) ORCID, RID
    Zanozina, Ekaterina M. (UFCH-W) RID, ORCID
    Chernov, Vladislav E. (UFCH-W)
    Číslo článku1083303
    Zdroj.dok.Proceedings of SPIE - The International Society of Optics and Photonics, 24th International Symposium on Atmospheric and Ocean Optics: Atmospheric Physics, Vol. 10833. - Bellingham : SPIE, 2018 / Matvienko G. G. ; Romanovskii O. A. - ISSN 0277-786X
    Poč.str.10 s.
    Forma vydáníTištěná - P
    AkceInternational Symposium on Atmospheric and Ocean Optics: Atmospheric Physics /24./
    Datum konání02.07.2018 - 05.07.2018
    Místo konáníTomsk
    ZeměRU - Rusko
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovaatomic oxygen ; Rydberg states ; IR-spectroscopy ; oscillator strenths
    Vědní obor RIVCF - Fyzikální chemie a teoretická chemie
    Obor OECDPhysical chemistry
    CEPGA13-07724S GA ČR - Grantová agentura ČR
    GA17-05076S GA ČR - Grantová agentura ČR
    EF16_019/0000778 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Institucionální podporaUFCH-W - RVO:61388955
    UT WOS000459714100002
    EID SCOPUS85061097370
    DOI https://doi.org/10.1117/12.2503552
    AnotaceWe present the results of precise laboratory measurements of the infrared (IR) spectrum of neutral oxygen (O I) atom using the time-resolved IR Fourier transform spectroscopy technique in 800−13000 cm−1 range. Based on 135 measured lines (including 51 lines previously not observed in the laboratory) and taking into account all previous measurements of the O I spectrum, a reoptimization procedure was performed, resulting in an updated system of levels internally matched to an accuracy of at least 0.01 cm−1. A large array of oscillator strengths and transition probabilities is calculated in the considered spectral range.
    PracovištěÚstav fyzikální chemie J.Heyrovského
    KontaktMichaela Knapová, michaela.knapova@jh-inst.cas.cz, Tel.: 266 053 196
    Rok sběru2019
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.