Počet záznamů: 1  

Comparison of non-destructive sensing methods on surface created by waterjet technology

  1. 1.
    SYSNO ASEP0494135
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevComparison of non-destructive sensing methods on surface created by waterjet technology
    Tvůrce(i) Klich, Jiří (UGN-S) RID, ORCID
    Klichová, Dagmar (UGN-S) RID, ORCID
    Souček, Kamil (UGN-S) RID, ORCID
    Celkový počet autorů3
    Zdroj.dok.Advances in Manufacturing Engineering and Materials, Proceedings of the International Conference on Manufacturing Engineering and Materials (ICMEM 2018). - Basel : Springer Nature Switzerland AG 2019, 2019 / Hloch S. ; Klichová D. ; Krolczyk G. M. ; Chattopadhyaya S. ; Ruppenthalová L. - ISSN 2195-4356 - ISBN 978-3-319-99353-9
    Rozsah strans. 114-123
    Poč.str.10 s.
    Forma vydáníOnline - E
    AkceInternational Conference on Manufacturing Engineering and Materials (ICMEM 2018)
    Datum konání18.06.2018 - 22.06.2018
    Místo konáníNový Smokovec
    ZeměSK - Slovensko
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.CH - Švýcarsko
    Klíč. slovaX-Ray computed tomography ; optical profilometer ; digital microscope ; surface topography ; waterjet technology
    Vědní obor RIVJQ - Strojní zařízení a nástroje
    Obor OECDMaterials engineering
    CEPLO1406 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Institucionální podporaUGN-S - RVO:68145535
    UT WOS000462541600013
    EID SCOPUS85053463733
    DOI10.1007/978-3-319-99353-9_13
    AnotaceThe article is a response to the lack of information, especially in the area of non-destructive techniques suitable for wide practical application. The article deals with evaluation of the disintegrated material volume removed from the samples by a water jet. The study presents a quantified disintegrated material volume by means of an optical profilometer MicroProf FRT, a digital microscope VHX-5100 and X-ray computed micro-tomograph XT H 225 ST. Based on a comparison of measured data, it is possible to state that the methods of optical profilometer and a digital microscope give us very close volume values. While the values of the volume of removed material analysed by X-Ray μ-CT reach higher its values. After detailed analysis of the individual tomographic cross-sections in area of kerf surface it can be concluded that complex morphology of this surface can explain differences in the results. There are visible some re-entrant features like an overhangs and undercuts at the surface created by high pressure water jet.
    PracovištěÚstav geoniky
    KontaktLucie Gurková, lucie.gurkova@ugn.cas.cz, Tel.: 596 979 354
    Rok sběru2020
    Elektronická adresahttps://link.springer.com/chapter/10.1007/978-3-319-99353-9_13