Počet záznamů: 1  

Nanomechanical testing of an a-C:N nanolayer prepared by ion beam assisted deposition on Ti.sub.6./sub.Al.sub.4./sub.V alloy

  1. 1.
    SYSNO ASEP0486538
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevNanomechanical testing of an a-C:N nanolayer prepared by ion beam assisted deposition on Ti6Al4V alloy
    Tvůrce(i) Vlčák, P. (CZ)
    Šepitka, J. (CZ)
    Horaždovský, T. (CZ)
    Jirka, Ivan (UFCH-W) RID, ORCID
    Gregora, Ivan (FZU-D) RID, ORCID
    Němec, M. (CZ)
    Celkový počet autorů6
    Zdroj.dok.NANOCON 2015: 7th International Conference on Nanomaterials - Research and Application, Conference Proceedings. - Ostrava : TANGER, spol. s r.o., 2015 - ISBN 978-80-87294-63-5
    Rozsah strans. 68-72
    Poč.str.5 s.
    Forma vydáníTištěná - P
    AkceNANOCON 2015. International Conference /7./
    Datum konání14.10.2015 - 16.10.2015
    Místo konáníBrno
    ZeměCZ - Česká republika
    Typ akceEUR
    Jazyk dok.eng - angličtina
    Země vyd.CZ - Česká republika
    Klíč. slovacarbon-based materials ; hardness ; ion beam assisted deposition ; a-C:N nanolayer
    Vědní obor RIVBM - Fyzika pevných látek a magnetismus
    Obor OECDCondensed matter physics (including formerly solid state physics, supercond.)
    Institucionální podporaFZU-D - RVO:68378271 ; UFCH-W - RVO:61388955
    UT WOS000374708800010
    EID SCOPUS84962875087
    AnotaceWe applied ion beam assisted deposition for preparing a-C:N nanolayers on Ti6Al4V alloy. A Hysitron TI 950 TriboIndenter (TM) nanomechanical test instrument was used to assess the depth profiles of the mechanical properties on modified titanium substrates. Two methods were employed : a) quasistatic partial unload, and b) dynamic Continuous Measurement of X (CMX). The average nanoindentation hardness increased from HIT similar to 5GPa for a reference sample to HIT similar to 8.6 GPa for a sample coated by an a-C nanolayer, and to HIT similar to 11.5 GPa for a sample coated by an a-C:N nanolayer. The average storage modulus of the sample coated by a-C:N increased from E' similar to 130 GPa (reference sample) to E' similar to 155 GPa. The storage modulus of the sample coated by the a-C nanolayer was less than the storage modulus of the titanium substrate.