Počet záznamů: 1  

Atmospheric plasma treatment of detonation nanodiamonds in water

  1. 1.
    SYSNO ASEP0471054
    Druh ASEPA - Abstrakt
    Zařazení RIVO - Ostatní
    NázevAtmospheric plasma treatment of detonation nanodiamonds in water
    Tvůrce(i) Štenclová, Pavla (FZU-D) ORCID
    Fantova, V. (CZ)
    Artemenko, Anna (FZU-D) RID, ORCID
    Jirásek, Vít (FZU-D) RID
    Jíra, Jaroslav (FZU-D)
    Rezek, Bohuslav (FZU-D) RID, ORCID
    Kromka, Alexander (FZU-D) RID, ORCID, SAI
    Zdroj.dok.Development of Materials Science in Research and Education. Book of Abstracts of the 26th Joint Seminar. - Praha : Institute of Physics of the Czech Academy of Sciences, v. v. i., 2016 / Kožíšek Z. ; Král R. ; Zemenová P. - ISBN 978-80-905962-4-5
    S. 42
    Poč.str.1 s.
    Forma vydáníTištěná - P
    AkceJoint Seminar Development of Materials Science in Research and Education /26./
    Datum konání29.08.2016 - 02.09.2016
    Místo konáníPavlov
    ZeměCZ - Česká republika
    Typ akceEUR
    Jazyk dok.eng - angličtina
    Země vyd.CZ - Česká republika
    Klíč. slovadetonation nanodiamonds ; atmospheric plasma ; FTIR spectroscopy
    Vědní obor RIVBM - Fyzika pevných látek a magnetismus
    CEPGA15-01687S GA ČR - Grantová agentura ČR
    Institucionální podporaFZU-D - RVO:68378271
    AnotaceA novel method for modifying DNDs suspended in water by DC atmospheric plasma sustained above the water suspension was reported. DNDs were used in as-received form (labeled as H-DND) or after air-annealing (labeled as O-DND). The influence of applied voltage (10 and 15 kV) and treatment duration (1, 5 and 10 minutes) on the surface chemistry of DNDs was evaluated by FTIR spectroscopy. Plasma treated H-DND particles reveal i) decreasing ratio of CH3 to CH2 surface groups; ii) disappearance of double bonds present in the graphitic shell of the particles and iii) re-arrangement of residual oxygen-containing moieties on the particle surface. In contrast to H-DNDs, the chemical state of O-DND surface was not affected by plasma treatment. In this case, newly formed doublet at 1580 and 1604 cm-1 was detected whose origin is not clear yet. Complementary XPS and Raman measurements did not reflect any changes of DNDs after the plasma treatment.
    PracovištěFyzikální ústav
    KontaktKristina Potocká, potocka@fzu.cz, Tel.: 220 318 579
    Rok sběru2017
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.