Number of the records: 1  

Plasma parameters in positive voltage pulses of bipolar HiPIMS discharge determined by Langmuir probe with a sub-microsecond time resolution

  1. 1.
    SYSNO ASEP0534023
    Document TypeJ - Journal Article
    R&D Document TypeJournal Article
    Subsidiary JČlánek ve WOS
    TitlePlasma parameters in positive voltage pulses of bipolar HiPIMS discharge determined by Langmuir probe with a sub-microsecond time resolution
    Author(s) Pajdarova, A.D. (CZ)
    Kozák, T. (CZ)
    Hubička, Zdeněk (FZU-D) RID, ORCID, SAI
    Čada, Martin (FZU-D) RID, ORCID, SAI
    Mareš, P. (CZ)
    Čapek, J. (CZ)
    Number of authors6
    Article number085016
    Source TitlePlasma Sources Science & Technology. - : Institute of Physics Publishing - ISSN 0963-0252
    Roč. 29, č. 8 (2020), s. 1-11
    Number of pages11 s.
    Languageeng - English
    CountryGB - United Kingdom
    Keywordsthin-films ; HiPIMS ; bipolar HiPIMS ; positive pulse ; plasma diagnostics ; magnetron ; Langmuir probe diagnostics
    Subject RIVBL - Plasma and Gas Discharge Physics
    OECD categoryFluids and plasma physics (including surface physics)
    R&D ProjectsFV30177 GA MPO - Ministry of Industry and Trade (MPO)
    Method of publishingLimited access
    Institutional supportFZU-D - RVO:68378271
    UT WOS000568418000001
    EID SCOPUS85092265900
    DOI10.1088/1361-6595/aba773
    AnnotationWe have determined the local plasma parameters using the Langmuir probe measurements with a sub-microsecond time resolution during positive voltage pulses of a bipolar high-power impulse magnetron sputtering discharge using an unbalanced magnetron with a titanium target. The effects of the positive voltage pulse amplitude and the delay between the negative voltage pulse end and the positive voltage pulse initiation are investigated as well as the spatial dependence of the plasma parameters at three distances from the target. From the results, the values of the average energy flux of ions during the positive voltage pulse to the substrate are estimated. We have found that the time evolution of the plasma parameters has similar developments which are independent of the positive voltage pulse parameters and the distance from the target, although the values of the plasma parameters are different.
    WorkplaceInstitute of Physics
    ContactKristina Potocká, potocka@fzu.cz, Tel.: 220 318 579
    Year of Publishing2021
    Electronic addresshttps://doi.org/10.1088/1361-6595/aba773
Number of the records: 1  

  This site uses cookies to make them easier to browse. Learn more about how we use cookies.