Number of the records: 1  

Application of hot-wire anemometry in a wind tunnel modelling of gaseous pollutants spreading

  1. 1.
    0103523 - UT-L 20040029 RIV CZ eng C - Conference Paper (international conference)
    Moryń-Kucharczyk, E. - Jonáš, Pavel - Mazur, Oton - Uruba, Václav
    Application of hot-wire anemometry in a wind tunnel modelling of gaseous pollutants spreading.
    [Použití anemometru se žhaveným drátkem při modelování šíření škodlivin v aerodynamickém tunelu.]
    Engineering mechanics 2004. Praha: Ústav termomechaniky AV ČR, 2004 - (Zolotarev, I.; Poživilová, A.), s. 191-192. ISBN 80-85918-88-9.
    [National conference with international participation : Engineering mechanics 2004. Svratka (CZ), 10.05.2004-13.05.2004]
    R&D Projects: GA MŠMT OC 715.90
    Institutional research plan: CEZ:AV0Z2076919
    Keywords : thermo-anemometer * steam turbineconcentration
    Subject RIV: BK - Fluid Dynamics

    Measurement of molar concentration in CO2 jet issuing from a narrow pipe into an air stream is described. Two methods of concentration measurement have been compared - using the analyser Guardian and using a special hot-sensors probe.

    Je popsáno měření molární koncentrace CO2 vytékajícího z úzké trubice do vzdušného proudu. Byly porovnány dvě metody měření koncentrace ato analyzátor Guardian a speciální sonda se žhavenými čidly.
    Permanent Link: http://hdl.handle.net/11104/0010830

     
     