Number of the records: 1
Power input prediction in agitated gas-liquid contractors with non-coalescent batch
- 1.0508030 - ÚH 2020 RIV DE eng J - Journal Article
Kracík, T. - Moucha, T. - Petříček, Radim
Power input prediction in agitated gas-liquid contractors with non-coalescent batch.
Chemical Engineering & Technology. Roč. 42, č. 12 (2019), s. 2673-2680. ISSN 0930-7516. E-ISSN 1521-4125
Institutional support: RVO:67985874
Keywords : fermenter * multiple impellers * non-coalescent media * power input prediction
OECD category: Fluids and plasma physics (including surface physics)
Impact factor: 1.543, year: 2019
Method of publishing: Limited access
https://onlinelibrary.wiley.com/doi/full/10.1002/ceat.201900165
Volumetric mass transfer coefficients, kLa, just as power input are considered as essential parameters for mechanically agitated gas-liquid contactors in relation to their optimization and design. The nowledge of power input is crucial for the prediction of other mass transfer characteristics. A power input correlation is created for the industrial design of the process with a non-coalescent batch that
would be appropriate for a broad range of operational conditions. The recommended resulting correlation is able to predict the power input for impellers in industrial-scale design for a significant scope of operational conditions.
Permanent Link: http://hdl.handle.net/11104/0301969
Number of the records: 1