    Modification of the luminol solution by means of addition of various complexones and surfactants has been investigated to eliminate interferences from gaseous co-pollutants in the determination of ambient nitrogen dioxide using a chemiluminescence aerosol detector. The simultaneous presence of EDTA and triton X-100 together with sulphite and iodide in the luminol solution suppressed interferences from ozone and peroxyacetyl nitrate to a negligible level and no scrubbers or corrections of the NO2 measurements were needed.