Počet záznamů: 1  

Measurement of capillary lenght from 3D images acquired by confocal microscopy using image analysis and stereology

  1. 1.
    0355547 - FGÚ 2011 RIV US eng J - Článek v odborném periodiku
    Kubínová, Lucie - Janáček, Jiří - Eržen, I. - Mao, X. W.
    Measurement of capillary lenght from 3D images acquired by confocal microscopy using image analysis and stereology.
    Microscopy and Microanalysis. Roč. 16, Suppl.2 (2010), s. 736-737. ISSN 1431-9276. E-ISSN 1435-8115.
    [Microscopy and Microanalysis 2010. Portland, 01.08.2010-05.08.2010]
    Grant CEP: GA MŠMT(CZ) LC06063; GA MŠMT(CZ) ME09010; GA MŠMT(CZ) MEB090910; GA ČR(CZ) GA304/09/0733
    Výzkumný záměr: CEZ:AV0Z50110509
    Klíčová slova: capillary length * confocal microscopy * image analysis
    Kód oboru RIV: EA - Morfologické obory a cytologie
    Impakt faktor: 2.179, rok: 2010

    Capillaries in rat brain and skeletal muscles were measured either by automated methods or by interactive procedure by counting intersections of the capillaries with 3D virtual grid of planes or spheres or by manual tracing of the capillaries. The precision of the methods is comparable. The automated methods cannot be used on images with poor contrast
    Trvalý link: http://hdl.handle.net/11104/0194293

     
     
Počet záznamů: 1  