Application of a Bonner sphere spectrometer for determination of the energy spectra of neutrons generated by ≈1 MJ plasma focus

  1. 1.
    0352718 - FZU-D 2011 RIV US eng J - Článek v odborném periodiku
    Králík, M. - Krása, Josef - Velyhan, Andriy - Scholz, M. - Ivanova-Stanik, I.M. - Bienkowska, B. - Miklaszewski, R. - Schmidt, H. - Řezáč, K. - Klír, D. - Kravárik, J. - Kubeš, P.
    Application of a Bonner sphere spectrometer for determination of the energy spectra of neutrons generated by ≈1 MJ plasma focus.
    Review of Scientific Instruments. Roč. 81, č. 11 (2010), 113503/1-113503/5 ISSN 0034-6748
    Grant CEP: GA MŠk LA08024
    Grant ostatní: FP-6 EU(XE) RITA-CT2006-26095
    Výzkumný záměr: CEZ:AV0Z10100523
    Klíčová slova: plasma focus * fusion DD neutrons * Bonner sphere spectrometer * energy spectra of scattered neutrons * unfolded and calculated spectra
    Kód oboru RIV: BL - Fyzika plazmatu a výboje v plynech
    Impakt faktor: 1.598, rok: 2010

    The spectra of neutrons outside the plasma focus device PF-1000 with an upper energy limit of _1 MJ was measured using a Bonner spheres spectrometer in which the active detector of thermal neutrons was replaced by nine thermoluminescent chips. As an a priori spectrum for the unfolding procedure, the spectrum calculated by means of the Monte Carlo method with a simplified model of the discharge chamber was selected. Differences between unfolded and calculated spectra are discussed with respect to properties of the discharge vessel and the laboratory layout.
    Trvalý link: http://hdl.handle.net/11104/0192166