Počet záznamů: 1

Characteristics of edgeless silicon detectors for the Roman Pots of the TOTEM experiment at the LHC

  1. 1.
    0345246 - FZU-D 2011 RIV NL eng J - Článek v odborném periodiku
    Ruggiero, G. - Avati, V. - Antchev, G. - Deile, M. - Eggert, K. - Eremin, V. - Kašpar, Jan - Niewiadomski, H. - Petajajarvi, J. - Radicioni, E. - Ravotti, F. - Radermacher, E. - Snoeys, W. - Spearman, W. - Wu, J.
    Characteristics of edgeless silicon detectors for the Roman Pots of the TOTEM experiment at the LHC.
    Nuclear Instruments & Methods in Physics Research Section A. Roč. 604, 1-2 (2009), s. 242-245 ISSN 0168-9002.
    [International Conference on Position Sensitive Detectors /8./. Glasgow, 01.09.2008-05.09.2008]
    Grant CEP: GA MŠk LA08015
    Výzkumný záměr: CEZ:AV0Z10100502
    Klíčová slova: silicon edgeless detctors * radiation hardness
    Kód oboru RIV: BF - Elementární částice a fyzika vys. energií
    Impakt faktor: 1.317, rok: 2009

    TOTEM Roman Pot microstrip edgeless silicon detectors, fabrikated with standard planar technology, reach full sensitivity within 50 μm from the cut edge and can operate with high bias voltage at room temperature.
    Trvalý link: http://hdl.handle.net/11104/0186562