Search results
- 1.0585501 - FZÚ 2024 RIV CZ cze Z - Pilot plant, v. technol., variety, breed
Štarman, S. - Kváča, Z. - Lančok, Ján
Ultrazvuková radiační vlnová litografie atomizačních částic.
[Ultrasonic radiation wave lithography of atomizing particles.]
Internal code: FW01010279-V4 ; 2024
Technical parameters: Pracovní procesy pro sonolitografii ultazvukových polí
Economic parameters: Ultrazvuková vlnová litografie, do 5 mil. Kč
R&D Projects: GA TA ČR(CZ) FW01010279
Institutional support: RVO:68378271
Keywords : sonolithography * ultrasonic transducer
OECD category: Materials engineering
Permanent Link: https://hdl.handle.net/11104/0353217 - 2.0585500 - FZÚ 2024 RIV CZ cze Z - Pilot plant, v. technol., variety, breed
Štarman, S. - Kváča, Z. - Lančok, Ján
Ultrazvuková radiační energetická litografie sonopolymerů.
[Ultrasonic radiation energy lithography of sonopolymers.]
Internal code: FW01010279-V2 ; 2022
Technical parameters: Simulace ultrazvukových polí a stanovení jejich parametrů, stanovení parametrů piezokeramiky, výběr litografických technik a roztoků, litografie pomocí 2D stroje pro maskování a následné leptání, kontaktování vývodů pomocí ultrazvuku, měření charakteristik měniče, zapouzdření měničů
Economic parameters: poloprovoz ultrazvukové litografie do 5 milionů Kč
R&D Projects: GA TA ČR(CZ) FW01010279
Institutional support: RVO:68378271
Keywords : sonolithography * ultrasonic transducer * sonopolymer
OECD category: Materials engineering
Permanent Link: https://hdl.handle.net/11104/0353216 - 3.0571758 - ÚMG 2024 RIV GR eng J - Journal Article
Mikyšková, Romana - Sapega, Olena - Psotka, M. - Novotný, Ondřej - Hodný, Zdeněk - Bálintová, Soňa - Malinak, D. - Svobodová, J. - Andrýs, R. - Ryšánek, David - Musílek, K. - Reiniš, Milan
STAT3 inhibitor Stattic and its analogues inhibit STAT3 phosphorylation and modulate cytokine secretion in senescent tumour cells.
Molecular Medicine Reports. Roč. 27, č. 4 (2023), č. článku 81. ISSN 1791-2997. E-ISSN 1791-3004
R&D Projects: GA MŠMT LX22NPO5102; GA MZd NV18-05-00562
Institutional support: RVO:68378050
Keywords : cellular senescence * docetaxel * signal transducer and activator of transcription 3 inhibition * Stattic * senescence-associated secretory phenotype
OECD category: Immunology
Impact factor: 3.4, year: 2022
Method of publishing: Open access
https://www.spandidos-publications.com/10.3892/mmr.2023.12968
Permanent Link: https://hdl.handle.net/11104/0343048File Download Size Commentary Version Access Mikyskova_2023_CC_BY.pdf 1 5 MB Publisher’s postprint open-access - 4.0536531 - BFÚ 2021 RIV CH eng J - Journal Article
Lenart, S. - Lenart, P. - Šmarda, J. - Remsik, J. - Souček, Karel - Beneš, P.
Trop2: Jack of All Trades, Master of None.
Cancers (Basel). Roč. 12, č. 11 (2020), č. článku 3328. E-ISSN 2072-6694
R&D Projects: GA MZd(CZ) NV17-28518A; GA MZd(CZ) NV18-08-00245
Institutional support: RVO:68081707
Keywords : antibody-drug conjugate * squamous-cell carcinoma * signal transducer 2 * sacituzumab govitecan * prostate-cancer * lung-cancer
OECD category: Oncology
Impact factor: 6.639, year: 2020
Method of publishing: Open access
http://apps.webofknowledge.com/InboundService.do?customersID=Alerting&mode=FullRecord&IsProductCode=Yes&product=WOS&Init=Yes&Func=Frame&DestFail=https%3A%2F%2Fwww.webofknowledge.com&action=retrieve&SrcApp=Alerting&SrcAuth=Alerting&SID=C1pXEQmefCtg1cvGeE2&UT=WOS%3A000592751100001
Permanent Link: http://hdl.handle.net/11104/0314304 - 5.0532044 - ÚTAM 2021 RIV CZ cze L - Prototype, f. module
Bayer, Jan - Černý, Miloš - Urushadze, Shota
Snímač posunutí DSP01 pro sledování dynamické odezvy stavebních konstrukcí na nízkých úrovních.
[Displacement sensor DSP01 for recording the dynamic response of building structures at low levels.]
Internal code: FVZ-NAKI-040-DSP01 ; 2020
Technical parameters: Zařízení je umístěno v laboratoři Centrum experimentální mechaniky, Ústav teoretické a aplikované mechaniky AV ČR, Prosecká 809/76, Praha 9
Economic parameters: Specifické zařízení umožňující měření dynamické odezvy konstrukce na velmi nízkých úrovních a při nízkých frekvencích
R&D Projects: GA MK(CZ) DG18P02OVV040
Keywords : vibration measurement * displacement transducer * strain gauge * micro-seismicity
OECD category: Civil engineering
Permanent Link: http://hdl.handle.net/11104/0310658File Download Size Commentary Version Access 0532044_2020_Bayer_et_al_FVZ-NAKI-040-DSP01_FVZ.pdf 13 2 MB Other open-access - 6.0512136 - ÚCHP 2020 RIV GB eng J - Journal Article
Koštejnová, Lucie - Přibyl, M. - Koštejn, Martin - Kuncová, Gabriela
Analytical Characteristics of a Glucose Sensor with an Optical oxygen Transducer for the Monitoring of Biotechnological Processes.
Measurement Science and Technology. Roč. 30, č. 1 (2019), č. článku 015103. ISSN 0957-0233. E-ISSN 1361-6501
Institutional support: RVO:67985858
Keywords : optical oxygen transducer * analytical characteristics * mathematical modelling
OECD category: Bioprocessing technologies (industrial processes relying on biological agents to drive the process) biocatalysis, fermentation
Impact factor: 1.857, year: 2019
Method of publishing: Limited access
Permanent Link: http://hdl.handle.net/11104/0302346File Download Size Commentary Version Access 0512136.pdf 0 3.4 MB Author’s postprint require - 7.0502111 - ÚEM 2019 RIV CZ cze L - Prototype, f. module
Jílek, Milan - Bureš, Zbyněk
Sonda pro měření otoakustických emisí u lidí.
[Probe for measurement of otoacoustic emissions in human subjects.]
Internal code: DP17001 ; 2018
Technical parameters: Sonda obsahuje dva elektromagnetické měniče označované jako „balaced armature speakears“ a jeden elektrostatický elektretový mikrofon. Frekvenční rozsah stimulace je 800 Hz až 18 kHz, frekvenční rozsah snímání je 50 Hz až 20 kHz. Zkreslení stimulace nepřesahuje v rozsahu používaných intenzit 5 %, zkreslení mikrofonu je zanedbatelné. Ekvivalentní šum mikrofonu je 24 dB s filtrem A. Rozměry sondy jsou přibližně: průměr 4 mm, délka 10 mm a délka připojeného kabelu 3 m.
Economic parameters: Ve spojitosti s vyvíjeným hardwarem a softwarem povede ke snížení nákladů na audiometrická vyšetření vytvořením finančně dostupnější alternativy ke komerčním audiologickým přístrojům a dále ke zvýšení přesnosti měření. V současnosti není možné spolehlivě určit ekonomické aspekty, neboť komerční využití v klinické praxi závisí na dalších, aktuálně nevyčíslených faktorech.
R&D Projects: GA TA ČR(CZ) TG01010135
Institutional support: RVO:68378041
Keywords : audiometry * hearing * otoacoustic emissions * miniature electroacoustic transducer
OECD category: Otorhinolaryngology
Permanent Link: http://hdl.handle.net/11104/0294072 - 8.0495298 - ÚTAM 2019 RIV cze P1 - User Module
Wolf, Benjamin - Koudelková, Veronika
Zařízení pro měření růstu krystalů, zejména v solném roztoku.
[A crystal growth measurement device, especially in a saline solution.]
2018. Owner: Ústav teoretické a aplikované mechaniky AV ČR, v. v. i. Date of the utility model acceptance: 13.11.2018. Utility model number: 32322
R&D Projects: GA ČR(CZ) GBP105/12/G059
Institutional support: RVO:68378297
Keywords : crystallization force * soluble salts * capacitive transducer
OECD category: Civil engineering
http://isdv.upv.cz/doc/FullFiles/UtilityModels/FullDocuments/FDUM0032/uv032322.pdf
Permanent Link: http://hdl.handle.net/11104/0289551 - 9.0465498 - ÚT 2017 RIV CZ cze J - Journal Article
Kober, Jan - Převorovský, Zdeněk
Kalibrace piezoelektrických měničů pomocí časově reverzní akustiky.
[Transducer frequency response variations investigated by time reversal calibration.]
NDT Welding Bulletin. Roč. 26, č. 3 (2016), s. 15-17. ISSN 1213-3825.
[DEFEKTOSKOPIE 2016 NDE for Safety /46./. Luhačovice, 08.11.2016-10.11.2016]
Institutional support: RVO:61388998
Keywords : calibration * time reversal * transducer * frequency response
Subject RIV: BI - Acoustics
Permanent Link: http://hdl.handle.net/11104/0266078 - 10.0465250 - ÚT 2017 CZ eng A - Abstract
Kober, Jan - Převorovský, Zdeněk
Transducer frequency response variations investigated by time reversal calibration.
NDT Welding Bulletin. Pavel Turek-Agentura Tiret. Roč. 26, č. 2 (2016), A16-A16. ISSN 1213-3825.
[Europen Conference on Acoustic Emission Testing /32./. 07.09.2016-09.09.2016, Praha]
Institutional support: RVO:61388998
Keywords : calibration * time reversal * transducer * frequency response
Subject RIV: BI - Acoustics
Permanent Link: http://hdl.handle.net/11104/0266510