Search results
- 1.0576348 - ÚIACH 2024 IT eng A - Abstract
Gogaľová, Zuzana - Šesták, Jozef - Lunerová, K.
Compact absorbance detector for portable microcolumn liquid chromatography instrument.
ITP 2023. Abstracts. 2023. s. 139-139.
[International Symposium on Electro- and Liquid-Phase Separation Techniques /29./ ITP 2023. 13.09.2023-17.09.2023, San Felice Circeo]
R&D Projects: GA MV(CZ) VI04000062
Institutional support: RVO:68081715
Keywords : absorbance detection * capillary flow cell * effective optical path * portable HPLC * miniaturization
OECD category: Analytical chemistry
Permanent Link: https://hdl.handle.net/11104/0345911File Download Size Commentary Version Access 0576348.pdf 1 645.8 KB Other open-access - 2.0570308 - ÚIACH 2023 RIV CZ cze L - Prototype, f. module
Vaněk, J. - Šesták, Jozef - Lunerová, K. - Kubíček, O. - Králík, L. - Tanzinger, L. - Rosenbergová, K. - Břínek, J. - Dědič, J. - Duša, Filip - Horká, Marie - Kahle, Vladislav - Karásek, Pavel - Moravcová, Dana - Planeta, Josef - Roth, Michal - Šalplachta, Jiří - Gogaľová, Zuzana
Inovovaný miniaturizovaný kapilární kapalinový chromatograf s UV/Vis a fluorescenční detekcí.
[Innovated miniaturized capillary liquid chromatograph with UV/Vis and fluorescence detector.]
Internal code: portable_LC_2022 ; 2022
Technical parameters: Průtok mobilní fáze: 5-25 μL/min, Maximální tlak: 100 MPa, Dávkovaný objem vzorku: 0.05 / 3µL, RSD retenčního času: < 1 %, RSD plochy píku: < 5 %, Kolonový termostat: do 70 °C ±0.2 °C, min 5 °C nad okolní teplotou, Výdrž na akumulátor: min. 8 hodin (okolní teplota 25 °C, akumulátor 14,8 V/7,8 Ah), Rozměry:420 x 350 x 180 mm (ve stavu pro transport), Hmotnost:9,5 kg
Economic parameters: Neuvádí se, výsledek je využíván příjemcem
R&D Projects: GA MV(CZ) VI04000062
Institutional support: RVO:68081715
Keywords : portable liquid chromatograph * microcolumn liquid chromatography * simultaneous absorbance-fluorescence detection
OECD category: Analytical chemistry
Permanent Link: https://hdl.handle.net/11104/0341598File Download Size Commentary Version Access 0570308.pdf 0 1.8 MB Author’s postprint require - 3.0570307 - ÚIACH 2023 RIV CZ cze L - Prototype, f. module
Vaněk, J. - Šesták, Jozef - Lunerová, K. - Kubíček, O. - Králík, L. - Tanzinger, L. - Rosenbergová, K. - Břínek, J. - Dědič, J. - Duša, Filip - Horká, Marie - Kahle, Vladislav - Karásek, Pavel - Moravcová, Dana - Planeta, Josef - Roth, Michal - Šalplachta, Jiří - Gogaľová, Zuzana
Inovovaný optický detektor na bázi CCD spektrometru.
[Innovated CCD spectrometer-based photometry detector.]
Internal code: mini_photo_det_2022 ; 2022
Technical parameters: Průtok kapaliny:5-25 μL/min, Objem detekční cely: 80 nL, Optická dráha:1 mm, Šum: 1 mAU při 10 Hz, Rozptýlené světlo:< 0,2 %, Fluorescenční detekce: 1 pg anthracen, excitace 365 nm, emise 400 nm, 5 Hz, Dynamický rozsah: 2000:1 – absorpce, 3000:1 – fluorescence, Rozměry: 250 x 150 x 100 mm, Hmotnost: 0,5 kg
Economic parameters: Neuvádí se, výsledek je využíván příjemcem
R&D Projects: GA MV(CZ) VI04000062
Institutional support: RVO:68081715
Keywords : miniaturised detection cell * light emitting diode * CCD spectrometer * simultaneous absorbance-fluorescence detection
OECD category: Analytical chemistry
Permanent Link: https://hdl.handle.net/11104/0341597File Download Size Commentary Version Access 0570307.pdf 0 994.4 KB Author’s postprint require - 4.0549519 - ÚJF 2022 RIV CH eng J - Journal Article
Cutroneo, Mariapompea - Havránek, Vladimír - Macková, Anna - Malinský, Petr - Silipigni, L. - Slepička, P. - Fajstavr, D. - Torrisi, L.
Synthesis of Porous Polydimethylsiloxane Gold Nanoparticles Composites by a Single Step Laser Ablation Process.
International Journal of Molecular Sciences. Roč. 22, č. 22 (2021), č. článku 12155. E-ISSN 1422-0067
R&D Projects: GA MŠMT EF16_013/0001812; GA ČR GA19-02482S; GA MŠMT LM2015056
Research Infrastructure: CANAM II - 90056
Institutional support: RVO:61389005
Keywords : absorbance * curing time * laser ablation in medium * nanoparticles * Polydimethylsiloxane * porous composite * scanning electron microscopy
OECD category: Atomic, molecular and chemical physics (physics of atoms and molecules including collision, interaction with radiation, magnetic resonances, Mössbauer effect)
Impact factor: 6.208, year: 2021
Method of publishing: Open access
https://doi.org/10.3390/ijms222212155
Permanent Link: http://hdl.handle.net/11104/0325514File Download Size Commentary Version Access 0549519.pdf 0 3.8 MB Open Access - CC licence Author’s postprint open-access - 5.0543679 - ÚCHP 2022 CZ eng K - Conference Paper (Czech conference)
Dolai, Susmita
Solvent Assisted 2D Mesoporous g-C3N4 Modification for Catalytic Application.
Proceedings of Abstracts. Prague: Institute of Chemical Process Fundamentals of the CAS, v. v. i., 2021 - (Bendová, M.; Wagner, Z.), s. 12-13. ISBN 978-80-86186-41-2.
[Bažant Postgraduate Conference 2021. Prague (CZ), 23.06.2021-26.06.2021]
Institutional support: RVO:67985858
Keywords : CN materials * catalyticapplication * absorbance spectra
OECD category: Chemical process engineering
Permanent Link: http://hdl.handle.net/11104/0320860File Download Size Commentary Version Access SKMBT_22321070812073.pdf 10 572.2 KB Publisher’s postprint open-access - 6.0542125 - ÚJF 2022 RIV GB eng J - Journal Article
Cutroneo, Mariapompea - Havránek, Vladimír - Macková, Anna - Malinský, Petr - Torrisi, Alfio - Silipigni, L. - Slepička, P. - Fajstavr, D. - Torrisi, L.
The characterisation of polydimethylsiloxane containing gold nanoparticles as a function of curing time.
Surface and Interface Analysis. Roč. 53, č. 7 (2021), s. 618-626. ISSN 0142-2421. E-ISSN 1096-9918
R&D Projects: GA ČR GA19-02482S; GA MŠMT EF16_013/0001812
Research Infrastructure: CANAM II - 90056
Institutional support: RVO:61389005
Keywords : absorbance * atomic-force microscopy * curing time * nanoparticles * porous polydimethylsiloxane * scanning electron microscopy
OECD category: Atomic, molecular and chemical physics (physics of atoms and molecules including collision, interaction with radiation, magnetic resonances, Mössbauer effect)
Impact factor: 1.702, year: 2021
Method of publishing: Limited access
https://doi.org/10.1002/sia.6948
Permanent Link: http://hdl.handle.net/11104/0320319 - 7.0539341 - ÚIACH 2021 RIV CZ cze L - Prototype, f. module
Šesták, Jozef - Lunerová, K. - Kahle, Vladislav
Přenosný kapilární kapalinový chromatograf.
[Portable capillary liquid chromatograph.]
Internal code: portable_LC_2020 ; 2020
Technical parameters: Průtok mobilní fáze:1-10 μL/min, Maximální tlak:35 MPa, Dávkovaný objem vzorku:0.5-5 μL, RSD retenčního času: < 0.5 %, RSD plochy píku:< 5 %, Kolonový termostat:±0.2 °C, min 5 °C nad okolní teplotou, Výdrž na akumulátor:min. 8 hodin (okolní teplota 25 °C, akumulátor 14,8 V/5,2 Ah), Rozměry:430 x 380 x 154 mm (ve stavu pro transport), Hmotnost:9 kg
Economic parameters: Neuvádí se, výsledek je využíván příjemcem.
R&D Projects: GA MV VI20172020069
Institutional support: RVO:68081715
Keywords : portable liquid chromatograph * microcolumn liquid chromatography * simultaneous absorbance-fluorescence detection
OECD category: Analytical chemistry
Permanent Link: http://hdl.handle.net/11104/0317030File Download Size Commentary Version Access 0539341.pdf 2 6.7 MB Author’s postprint require - 8.0524063 - ÚIACH 2021 RIV NL eng J - Journal Article
Šesták, Jozef - Planeta, Josef - Kahle, Vladislav
Compact optical detector utilizing light emitting diodes, 50 nL L-shaped silica capillary cell and CCD spectrometer for simultaneous multi-wavelength monitoring of absorbance and fluorescence in microcolumn liquid chromatography.
Analytica Chimica Acta. Roč. 1112, May (2020), s. 80-91. ISSN 0003-2670. E-ISSN 1873-4324
R&D Projects: GA ČR(CZ) GA19-00742S; GA MV VI20172020069
Institutional support: RVO:68081715
Keywords : simultaneous absorbance-fluorescence detection * miniaturised detection cell * microcolumn liquid chromatography
OECD category: Analytical chemistry
Impact factor: 6.558, year: 2020
Method of publishing: Limited access
Permanent Link: http://hdl.handle.net/11104/0308398File Download Size Commentary Version Access 0524063.pdf 8 2.3 MB Author’s postprint require - 9.0509158 - ÚIACH 2020 PL eng A - Abstract
Šesták, Jozef - Kahle, Vladislav
Combined photometric detector utilizing light emitting diodes, 50 nL silica capillary cell, and CCD spectrometer.
CECE 2019. Gdańsk: University of Gdańsk, 2019. s. 45-45.
[CECE 2019. International Interdisciplinary Meeting on Bioanalysis /16./. 24.09.2019-26.09.2019, Gdańsk]
R&D Projects: GA MV VI20172020069
Institutional support: RVO:68081715
Keywords : capillary LC * absorbance-fluorescence detector * capillary detection cell * CCD spectrometer * light-emitting diodes
OECD category: Analytical chemistry
Permanent Link: http://hdl.handle.net/11104/0299925File Download Size Commentary Version Access 05091580001.pdf 4 1.6 MB Other open-access - 10.0451414 - ÚT 2016 RIV cze P - Patent Document
Převorovský, Zdeněk - Chlada, Milan - Sladký, Petr
Způsob sledování procesu koroze potrubí a nádob.
[Method of monitoring corrosion process of piping and vessels.]
2015. Owner: Ústav termomechaniky AV ČR, v. v. i. Date of the patent acceptance: 30.09.2015. Patent Number: 305515
R&D Projects: GA MPO(CZ) FR-TI1/198
Institutional support: RVO:61388998
Keywords : corrosion process monitoring * piping and vessels * non-linear spectroscopy of elastic waves * shade and absorbance
Subject RIV: BI - Acoustics
http://spisy.upv.cz/Patents/FullDocuments/305/305515.pdf
Permanent Link: http://hdl.handle.net/11104/0253427