Search results

  1. 1.
    0586485 - ÚPT 2025 RIV US eng J - Journal Article
    Kratochvíla, Jiří - Jiřík, Radovan - Bartoš, Michal - Standara, M. - Starčuk jr., Zenon - Taxt, T.
    Blind deconvolution decreases requirements on temporal resolution of DCE-MRI: Application to 2nd generation pharmacokinetic modeling.
    Magnetic Resonance Imaging. Roč. 109, June (2024), s. 238-248. ISSN 0730-725X. E-ISSN 1873-5894
    R&D Projects: GA ČR(CZ) GA22-10953S; GA MŠMT(CZ) LM2023050
    Institutional support: RVO:68081731 ; RVO:67985556
    Keywords : DCE-MRI * Blind deconvolution * 2nd generation pharmacokinetic model * Temporal resolution
    Impact factor: 2.5, year: 2022
    Method of publishing: Limited access
    https://www.sciencedirect.com/science/article/pii/S0730725X24000754
    Permanent Link: https://hdl.handle.net/11104/0353995
     
     
  2. 2.
    0546148 - ÚPT 2022 RIV US eng J - Journal Article
    Taxt, T. - Andersen, E. - Jiřík, Radovan
    Single voxel vascular transport functions of arteries, capillaries and veins, and the associated arterial input function in dynamic susceptibility contrast magnetic resonance brain perfusion imaging.
    Magnetic Resonance Imaging. Roč. 84, December (2021), s. 101-114. ISSN 0730-725X. E-ISSN 1873-5894
    R&D Projects: GA MŠMT(CZ) LM2018129; GA MŠMT(CZ) EF16_013/0001775
    Institutional support: RVO:68081731
    Keywords : DSC-MRI * Brain perfusion * Vascular transport functions * Mean transit times * Arterial input functions
    OECD category: Medical engineering
    Impact factor: 3.130, year: 2021
    Method of publishing: Open access
    https://www.sciencedirect.com/science/article/pii/S0730725X21001387?via%3Dihub
    Permanent Link: http://hdl.handle.net/11104/0322701
     
     
  3. 3.
    0507813 - ÚPT 2020 RIV US eng J - Journal Article
    Jiřík, Radovan - Taxt, T. - Macíček, Ondřej - Bartoš, Michal - Kratochvíla, Jiří - Souček, Karel - Dražanová, Eva - Krátká, Lucie - Hampl, A. - Starčuk jr., Zenon
    Blind deconvolution estimation of an arterial input function for small animal DCE-MRI.
    Magnetic Resonance Imaging. Roč. 62, OCT (2019), s. 46-56. ISSN 0730-725X. E-ISSN 1873-5894
    R&D Projects: GA ČR(CZ) GA16-13830S; GA MŠMT ED0017/01/01; GA MŠMT(CZ) LO1212; GA MŠMT(CZ) EF16_013/0001775
    Institutional support: RVO:68081731 ; RVO:67985556 ; RVO:68081707
    Keywords : DCE-MRI * blind deconvolution * arterial input function
    OECD category: Medical laboratory technology (including laboratory samples analysis; Computer sciences, information science, bioinformathics (hardware development to be 2.2, social aspect to be 5.8) (UTIA-B); Medical laboratory technology (including laboratory samples analysis (BFU-R)
    Impact factor: 2.053, year: 2019
    Method of publishing: Limited access
    https://www.sciencedirect.com/science/article/pii/S0730725X18306763?via%3Dihub
    Permanent Link: http://hdl.handle.net/11104/0298781
     
     
  4. 4.
    0497932 - ÚPT 2019 RIV SK eng J - Journal Article
    Macíček, Ondřej - Jiřík, Radovan - Mikulka, J. - Bartoš, Michal - Šprláková, A. - Keřkovský, M. - Starčuk jr., Zenon - Bartušek, Karel - Taxt, T.
    Time-Efficient Perfusion Imaging Using DCE- and DSC-MRI.
    Measurement Science Review. Roč. 18, č. 6 (2018), s. 262-271. ISSN 1335-8871. E-ISSN 1335-8871
    R&D Projects: GA ČR(CZ) GA16-13830S; GA MŠMT(CZ) LO1212; GA MŠMT ED0017/01/01; GA MŠMT(CZ) LM2015062; GA MŠMT(CZ) EF16_013/0001775
    Institutional support: RVO:68081731 ; RVO:67985556
    Keywords : perfusion imaging * contrast agents * brain tumors * DCE-MRI * DSC-MRI
    OECD category: Medical engineering; Computer hardware and architecture (UTIA-B)
    Impact factor: 1.122, year: 2018
    Permanent Link: http://hdl.handle.net/11104/0290386
     
     
  5. 5.
    0494595 - ÚPT 2019 RIV US eng J - Journal Article
    Obad, N. - Espedal, H. - Jiřík, Radovan - Sakariassen, P.O. - Rygh, C. B. - Lund-Johansen, M. - Taxt, T. - Niclou, S.P. - Bjerkvig, R. - Keunen, O.
    Lack of functional normalisation of tumour vessels following anti-angiogenic therapy in glioblastoma.
    Journal of Cerebral Blood Flow and Metabolism. Roč. 38, č. 10 (2018), s. 1741-1753. ISSN 0271-678X. E-ISSN 1559-7016
    R&D Projects: GA ČR(CZ) GA16-13830S
    Institutional support: RVO:68081731
    Keywords : angiogenesis * bevacizumab * glioblastoma * hypoxia * perfusion * VEGF
    OECD category: Pharmacology and pharmacy
    Impact factor: 6.040, year: 2018
    Permanent Link: http://hdl.handle.net/11104/0287711
     
     
  6. 6.
    0489561 - ÚPT 2019 RIV US eng J - Journal Article
    Taxt, T. - Reed, R. K. - Pavlin, T. - Rygh, C. B. - Andersen, E. - Jiřík, Radovan
    Semi-parametric arterial input functions for quantitative dynamic contrast enhanced magnetic resonance imaging in mice.
    Magnetic Resonance Imaging. Roč. 46, FEB (2018), s. 10-20. ISSN 0730-725X. E-ISSN 1873-5894
    R&D Projects: GA MŠMT(CZ) LO1212; GA ČR(CZ) GA16-13830S
    Institutional support: RVO:68081731
    Keywords : DCE-MRI * blind deconvolution * arterial input function
    OECD category: Medical laboratory technology (including laboratory samples analysis
    Impact factor: 2.112, year: 2018
    Permanent Link: http://hdl.handle.net/11104/0283959
     
     
  7. 7.
    0467243 - ÚPT 2017 RIV US eng J - Journal Article
    Eskilsson, E. - Rosland, G.V. - Talasila, K.M. - Knappskog, S. - Keunen, O. - Sottoriva, A. - Foerster, S. - Solecki, G. - Taxt, T. - Jiřík, Radovan - Fritah, S. - Harter, P.N. - Valk, K. - Al Hossain, J. - Joseph, J.V. - Jahedi, R. - Saed, H.S. - Piccirillo, S.G. - Spiteri, I. - Leiss, L. - Euskirchen, P. - Graziani, G. - Daubon, T. - Lund-Johansen, M. - Enger, P.O. - Winkler, F. - Ritter, C. - Niclou, Simone P. - Watts, C. - Bjerkvig, R. - Miletic, H.
    EGFRvIII mutations can emerge as late and heterogenous events in glioblastoma development and promote angiogenesis through Src activation.
    Neuro-Oncology. Roč. 18, č. 12 (2016), s. 1644-1655. ISSN 1522-8517. E-ISSN 1523-5866
    R&D Projects: GA ČR GAP102/12/2380; GA MŠMT(CZ) LO1212
    Institutional support: RVO:68081731
    Keywords : angiogenesis * EGFR * EGFRvIII * glioblastoma * invasion
    Subject RIV: BH - Optics, Masers, Lasers
    Impact factor: 7.786, year: 2016
    Permanent Link: http://hdl.handle.net/11104/0265373
     
     
  8. 8.
    0466902 - ÚPT 2017 RIV US eng J - Journal Article
    Kratochvíla, Jiří - Jiřík, Radovan - Bartoš, M. - Standara, M. - Starčuk jr., Zenon - Taxt, T.
    Distributed capillary adiabatic tissue homogeneity model in parametric multi-channel blind AIF estimation using DCE-MRI.
    Magnetic Resonance in Medicine. Roč. 75, č. 3 (2016), s. 1355-1365. ISSN 0740-3194. E-ISSN 1522-2594
    R&D Projects: GA ČR GAP102/12/2380; GA MŠMT(CZ) LO1212; GA MŠMT ED0017/01/01
    Institutional support: RVO:68081731
    Keywords : dynamic contrast-enhanced magnetic resonance imaging * multi-channel blind deconvolution * arterial input function * impulse residue function * renal cell carcinoma
    Subject RIV: BM - Solid Matter Physics ; Magnetism
    Impact factor: 3.924, year: 2016
    Permanent Link: http://hdl.handle.net/11104/0265083
     
     
  9. 9.
    0451614 - ÚPT 2016 RIV US eng J - Journal Article
    Mézl, M. - Jiřík, Radovan - Harabiš, V. - Kolář, R. - Standara, M. - Nylund, K. - Gilja, O.H. - Taxt, T.
    Absolute Ultrasound Perfusion Parameter Quantification of a Tissue-Mimicking Phantom Using Bolus Tracking.
    IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control. Roč. 62, č. 5 (2015), s. 983-987. ISSN 0885-3010. E-ISSN 1525-8955
    R&D Projects: GA ČR GAP102/12/2380; GA MŠMT(CZ) LO1212
    Institutional support: RVO:68081731
    Keywords : indicator dilution models * contrast agents * blood-flow * in-vitro * validation
    Subject RIV: FS - Medical Facilities ; Equipment
    Impact factor: 2.287, year: 2015
    Permanent Link: http://hdl.handle.net/11104/0252745
     
     
  10. 10.
    0451248 - ÚPT 2016 RIV DE eng J - Journal Article
    Taxt, T. - Pavlin, T. - Reed, R. K. - Curry, F. R. - Andersen, E. - Jiřík, Radovan
    Using Single-Channel Blind Deconvolution to Choose the Most Realistic Pharmacokinetic Model in Dynamic Contrast-Enhanced MR Imaging.
    Applied Magnetic Resonance. Roč. 46, č. 6 (2015), s. 643-659. ISSN 0937-9347. E-ISSN 1613-7507
    R&D Projects: GA ČR GAP102/12/2380; GA MŠMT(CZ) LO1212
    Institutional support: RVO:68081731
    Keywords : blood-flow * magnetic resonance * kinetic parameters
    Subject RIV: BH - Optics, Masers, Lasers
    Impact factor: 0.884, year: 2015
    Permanent Link: http://hdl.handle.net/11104/0252476
     
     

  This site uses cookies to make them easier to browse. Learn more about how we use cookies.