Search results

  1. 1.
    0564998 - ÚJF 2023 RIV CH eng J - Journal Article
    Van Hoey, O. - Stolarczyk, L. - Lillhök, J. - Eliasson, L. - Mojzeszek, N. - Liszka, M. - Alkhiat, A. - Mares, V. - Trompier, F. - Trinkl, S. - Martinez-Rovira, I. - Romero-Exposito, M. - Domingo, C. - Ploc, Ondřej - Harrison, R. - Olko, P.
    Simulation and experimental verification of ambient neutron doses in a pencil beam scanning proton therapy room as a function of treatment plan parameters.
    Frontiers in Oncology. Roč. 12, SEP (2022), č. článku 903537. ISSN 2234-943X. E-ISSN 2234-943X
    R&D Projects: GA MŠMT EF15_003/0000481
    Institutional support: RVO:61389005
    Keywords : Proton therapy * Pencil beam scanned proton therapy * Neutron doses * Monte Carlo simulations * Out-of-field neutron doses in radiation therapy * Neutron measurements
    OECD category: Radiology, nuclear medicine and medical imaging
    Impact factor: 4.7, year: 2022
    Method of publishing: Open access
    https://doi.org/10.3389/fonc.2022.903537
    Permanent Link: https://hdl.handle.net/11104/0336565
    FileDownloadSizeCommentaryVersionAccess
    0564998.pdf01.9 MBOpen Access - CC licencePublisher’s postprintopen-access
     
     
  2. 2.
    0539709 - ÚJF 2022 RIV GB eng J - Journal Article
    Wochnik, A. - Stolarczyk, L. - Ambrožová, Iva - Davídková, Marie - De Saint-Hubert, M. - Domanski, S. - Domingo, C. - Kneževic, Z. - Kopec, R. - Kuc, M. - Majer, M. - Mojzeszek, N. - Mares, V. - Martinez-Rovira, I. - Caballero-Pachero, M. A. - Pyszka, E. - Swakoń, J. - Trinkl, S. - Tisi, M. - Harrison, R. - Olko, P.
    Out-of-field doses for scanning proton radiotherapy of shallowly located paediatric tumours-a comparison of range shifter and 3D printed compensator.
    Physics in Medicine and Biology. Roč. 66, č. 3 (2021), č. článku 035012. ISSN 0031-9155. E-ISSN 1361-6560
    EU Projects: European Commission(XE) 730983 - INSPIRE
    Institutional support: RVO:61389005
    Keywords : scanning proton radiotherapy * measurement of stray neutrons * ambient dose equivalent * active detectors * passive detectors * anthropomorphic paediatric phantom measurements * secondary radiation measurments
    OECD category: Radiology, nuclear medicine and medical imaging
    Impact factor: 4.174, year: 2021
    Method of publishing: Open access
    https://doi.org/10.1088/1361-6560/abcb1f
    Permanent Link: http://hdl.handle.net/11104/0317417
    FileDownloadSizeCommentaryVersionAccess
    0539709.pdf02.3 MBOpen Access - CC licencePublisher’s postprintopen-access
     
     
  3. 3.
    0444984 - ÚJF 2016 RIV US eng J - Journal Article
    Farah, J. - Mares, V. - Romero-Exposito, M. - Trinkl, S. - Domingo, C. - Dufek, V. - Klodowska, M. - Kubančák, Ján - Knezevic, Z. - Ploc, Ondřej … Total 19 authors
    Measurement of stray radiation within a scanning proton therapy facility: EURADOS WG9 intercomparison exercise of active dosimetry systems.
    Medical Physics. Roč. 42, č. 5 (2015), s. 2572-2584. ISSN 0094-2405. E-ISSN 2473-4209
    Institutional support: RVO:61389005
    Keywords : scanning proton therapy * measurement of stray neutrons * spectrometry * ambient dose eyuivalent * intercomparison
    Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders
    Impact factor: 2.496, year: 2015
    Permanent Link: http://hdl.handle.net/11104/0247414
     
     
  4. 4.
    0331468 - ÚJF 2010 RIV GB eng J - Journal Article
    Silari, M. - Agosteo, S. - Beck, P. - Bedogni, R. - Cale, E. - Caresana, M. - Domingo, C. - Donadille, L. - Dubourg, N. - Esposito, A. - Fehrenbacher, G. - Fernández, F. - Ferrarini, M. - Fiechtner, A. - Fuchs, A. - García, M. J. - Golnik, N. - Gutermuth, F. - Khurana, S. - Klages, T. - Latocha, M. - Mares, V. - Mayer, S. - Radon, T. - Reithmeier, H. - Rollet, S. - Roos, H. - Rühm, W. - Sandri, S. - Schardt, D. - Simmer, G. - Spurný, František - Trompier, F. - Villa-Grasa, C. - Weitzenegger, E. - Wiegel, B. - Wielunski, M. - Wissmann, F. - Zechner, A. - Zielczyński, M.
    Intercomparison of radiation protection protection devices in a high-energy stray neutron field. Part III: Instrument response.
    [Srovnání zařízení radiační ochrany v rozptýleném neutronovém poli o vysoké energii. Část III: Odezva přístroje.]
    Radiation Measurements. Roč. 44, 7-8 (2009), s. 673-691. ISSN 1350-4487. E-ISSN 1879-0925
    R&D Projects: GA AV ČR IAA100480902
    Institutional research plan: CEZ:AV0Z10480505
    Keywords : radiation protection devices * radiation field * detectors * dosemeters
    Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders
    Impact factor: 0.973, year: 2009
    Permanent Link: http://hdl.handle.net/11104/0176972
     
     


  This site uses cookies to make them easier to browse. Learn more about how we use cookies.