Search results
- 1.0189368 - UMCH-V 20033323 CH eng A - Abstract
Novotný ml., J. - Spěváček, V. - Dvořák, P. - Novotný, J. - Hrbáček, J. - Tintěra, J. - Vymazal, J. - Čechák, T. - Michálek, Jiří - Vacík, Jiří - Liščák, R.
Application of polymer-gel dosimeter for evaluation of relative dose distributions in stereotactic radiosurgery.
Abstracts. Geneve: European Society for Therapeutic Radiology and Oncology, 2003. s. -.
[Biennial ESTRO Meeting on Physics and Radiation Technology for Clinical Radiotherapy /7./. 13.09.2003-14.09.2003, Geneve]
R&D Projects: GA MZd NC7460
Institutional research plan: CEZ:AV0Z4050913
Keywords : stereotactic radiosurgery * polymer-gel dosimeter * three-dimensional dosimetry
Subject RIV: FD - Oncology ; Hematology
Permanent Link: http://hdl.handle.net/11104/0085184 - 2.0189365 - UMCH-V 20033320 JP eng A - Abstract
Novotný, J. - Spěváček, V. - Hrbáček, J. - Judas, L. - Novotný, J. - Dvořák, P. - Tlacháčová, D. - Schmitt, M. - Tintěra, J. - Vymazal, J. - Čechák, T. - Michálek, Jiří - Přádný, Martin - Liščák, R.
Measurement of relative dose distributions in stereotactic radiosurgery by the polymer-gel dosimeter.
Program & Abstracts. Kyoto: Science Council of Japan, 2003. s. -.
[International Stereotactic Radiosurgery Society Congress /6./. 22.06.2003-26.06.2003, Kyoto]
R&D Projects: GA MZd NC7460
Institutional research plan: CEZ:AV0Z4050913
Keywords : stereotactic radiosurgery * polymer-gel dosimeter
Subject RIV: FD - Oncology ; Hematology
Permanent Link: http://hdl.handle.net/11104/0085181 - 3.0173764 - UEM-P 20033088 CZ eng A - Abstract
Náměstková, Kateřina - Jirák, D. - Herynek, V. - Liščák, R. - Hájek, M. - Syková, Eva
Radiosurgical lesion of the rat hippocampus using the Leksell gama knife: relation between radiation dose and functional and structural damage.
Abstract Book (Sixth IBRO). Praha, 2003. s. 352. ISBN 80-239-0887-1.
[IBRO World Congress of Neuroscience /6./. 10.07.2003-15.07.2003, Praha]
R&D Projects: GA MŠMT LN00A065
Institutional research plan: CEZ:MSM 111300004
Keywords : Leksell gamma knife * radiosurgical lesion
Subject RIV: FH - Neurology
Permanent Link: http://hdl.handle.net/11104/0070790 - 4.0173513 - UEM-P 20010111 DE eng A - Abstract
Náměstková, Kateřina - Liščák, R. - Brožek, G. - Syková, Eva
Dose-dependent sparing of hipposampal function in a spatial navigation test after bilateral gamma irradiation of the adult rat hippocampus.
12th European Students´Conference at Charité for Medical Students and Young Doctors. Berlin: Faculty of Medicine, 2001. s. 212.
[12th European Students´Conference at Charité. 21.11.2001-25.11.2001, Berlin]
R&D Projects: GA ČR GA309/99/0657; GA MZd NF5161
Keywords : hippocampus
Subject RIV: FH - Neurology
Permanent Link: http://hdl.handle.net/11104/0070546