Search results
- 1.0212461 - UT-L 20030178 RIV SK eng C - Conference Paper (international conference)
Fuis, Vladimír
Analysis of the oblique loading of the hip joint endoprosthesis head with the shape deflections of the contact cones.
Mechanical Engineering 2003. Bratislava: STU Bratislava, 2003 - (Peciar, M.; Čerňanský, A.; Juriga, M.), s. 1-6. ISBN 80-227-1960-9.
[Mechanical Engineering 2003. Bratislava (SK), 05.11.2003-06.11.2003]
R&D Projects: GA ČR GA101/01/0974; GA ČR GP101/01/P039
Institutional research plan: CEZ:AV0Z2076919
Keywords : Hip joint endoprosthesis * ceramics head and stem shape deflections * oblique loading
Subject RIV: JH - Ceramics, Fire-Resistant Materials and Glass
Permanent Link: http://hdl.handle.net/11104/0108009 - 2.0212459 - UT-L 20030176 RIV SK eng C - Conference Paper (international conference)
Fuis, Vladimír
Analysis of the real shape deflections of the hip joint endoprosthesis stem and head cone areas on the stress in the ceramic head.
Mechanical Engineering 2003. Bratislava: STU Bratislava, 2003 - (Peciar, M.; Čerňanský, A.; Juriga, M.), s. 1-6. ISBN 80-227-1960-9.
[Mechanical Engineering 2003. Bratislava (SK), 05.11.2003-06.11.2003]
R&D Projects: GA ČR GP101/01/P039
Institutional research plan: CEZ:AV0Z2076919
Keywords : Hip joint endoprosthesis * ceramics head and stem shape deflections * computational modelling
Subject RIV: JH - Ceramics, Fire-Resistant Materials and Glass
Permanent Link: http://hdl.handle.net/11104/0108007 - 3.0212413 - UT-L 20030130 RIV CZ eng C - Conference Paper (international conference)
Fuis, Vladimír - Hlavoň, Pavel
Comparison of the computational and experimental modelling results of the hip joint endoprosthesis behaviour under pressing on the stem.
Experimental stress analysis 2003. Milovy: Brno University of Technology, FME, Institute of Mechanics o, 2003 - (Vlk, M.; Houfek, L.; Šlechtová, M.), s. 1-9. ISBN 80-214-2314-5.
[Experimental Stress Analysis 2003. Milovy (CZ), 03.06.2003-05.06.2003]
R&D Projects: GA ČR GP101/01/P039
Institutional research plan: CEZ:AV0Z2076919
Keywords : Hip joint endoprosthesis * measured inaccuraceis * strain measurement
Subject RIV: JH - Ceramics, Fire-Resistant Materials and Glass
Permanent Link: http://hdl.handle.net/11104/0107961 - 4.0212412 - UT-L 20030129 RIV CZ eng C - Conference Paper (international conference)
Fuis, Vladimír - Hlavoň, Pavel
Influence of the Measured Contact Cone Shape Deflections of the Hip Joint Endoprosthesis on the Stress and Reliability Values.
Engineering mechanics 2003. Praha: UTAM AV ČR, 2003 - (Náprstek, J.; Fischer, C.), s. 1-8. ISBN 80-86246-18-3.
[National Conference with International Participation "Engineering Mechanics 2003". Svratka (CZ), 12.05.2003-15.05.2003]
R&D Projects: GA ČR GP101/01/P039
Institutional research plan: CEZ:AV0Z2076919
Keywords : Hip joint endoprosthesis * manufacturing deflections * stress and reliability analyses
Subject RIV: JH - Ceramics, Fire-Resistant Materials and Glass
Permanent Link: http://hdl.handle.net/11104/0107960 - 5.0212411 - UT-L 20030128 RIV PL eng C - Conference Paper (international conference)
Fuis, Vladimír
Stress and reliability analyses of the hip joint endoprosthesis ceramic head with measured manufacturing inaccuracies.
Zeszyty naukowe katerdry mechaniki stosowanej. Jaworzynka: Politechnika Slaska, Katedra Mechaniky Stosowanej, Gliwice, 2003 - (Gzik, B.; Jureczko, P.; Manka, I.), s. 51-56. 21. ISBN 83-917224-3-0.
[Applied mechanics 2003. Jaworzynka (CZ), 24.03.2003-27.03.2003]
R&D Projects: GA ČR GP101/01/P039
Institutional research plan: CEZ:AV0Z2076919
Keywords : Hip joint endoprosthesis * measured inaccuraceis * computational modelling
Subject RIV: JH - Ceramics, Fire-Resistant Materials and Glass
Permanent Link: http://hdl.handle.net/11104/0107959 - 6.0212409 - UT-L 20030126 RIV AU eng C - Conference Paper (international conference)
Fuis, Vladimír
Stress and reliability analyses of ceramic femoral head of hip joint endoprosthesis, with view to local shape deviations of cone contact areas.
Medical Physics and Biomedical Engineering. Sydney: IFMBE, 2003 - (Allen, B.; Lovell, N.), s. 1-4. 4.
[World Congress on Medical Physics and Biomedical Engineering. Sydney (AU), 24.08.2003-29.08.2003]
R&D Projects: GA ČR GP101/01/P039
Institutional research plan: CEZ:AV0Z2076919
Keywords : Hip joint endoprosthesis * manufacturing deflections * computational modelling
Subject RIV: JH - Ceramics, Fire-Resistant Materials and Glass
www.wc2003.org
Permanent Link: http://hdl.handle.net/11104/0107957 - 7.0212229 - UT-L 20020175 RIV SK cze C - Conference Paper (international conference)
Fuis, Vladimír
Napjatostní analýza v keramické hlavici kyčelní endoprotézy s uvažováním reálných výrobních nepřesností.
[Stress analysis of hip joint endoprosthesis ceramic head with real manufacturing inaccuracies consideration.]
Mechanical Engineering 2002. Bratislava: STU Bratislava, 2002 - (Švarc, P.), s. 1-6. ISBN 80-227-1783-5.
[Mechanical Engineering 2002. Bratislava (SK), 23.10.2002-24.10.2002]
R&D Projects: GA ČR GP101/01/P039
Keywords : total hip joint endoprosthesis * computational modeling * manufacturing inaccuracies of contact areas
Subject RIV: JH - Ceramics, Fire-Resistant Materials and Glass
Permanent Link: http://hdl.handle.net/11104/0107777 - 8.0212207 - UT-L 20020153 RIV SIGLE CZ eng C - Conference Paper (international conference)
Fuis, Vladimír
Analysis of the measured production inaccuracies of the contact areas of the hip joint endoprosthesis parts.
Biomechanics of man 2002. Čejkovice: Faculty of Physical Education and Sport, Charles University, 2002 - (Jelen, K.; Kušová, S.; Chalupová, M.; Otáhal, J.), s. 196-199. ISBN 80-86317-23-4.
[Biomechanics of man 2002. Čejkovice (CZ), 12.11.2002-15.11.2002]
R&D Projects: GA ČR GP101/01/P039
Keywords : Hip joint endoprosthesis * measured inaccuraceis * computational modelling
Subject RIV: JH - Ceramics, Fire-Resistant Materials and Glass
Permanent Link: http://hdl.handle.net/11104/0107755 - 9.0212117 - UT-L 20020063 RIV CZ cze C - Conference Paper (international conference)
Fuis, Vladimír - Hlavoň, P.
Zkušenosti z měření výrobních nepřesností na kontaktních plochách dříku a hlavice kyčelní endoprotézy a jejich modelování.
[Experiences of the production inaccuracies measuring on the contact areas of the hip joint endoprosthesis stem and the head and its modelling.]
Inženýrská mechanika 2002. Brno: VUT, 2002 - (Houfek, L.; Hlavoň, P.; Krejčí, P.), s. 1-7. ISBN 80-214-2109-6.
[National conference with international participation Engineering Mechanics 2002. Svratka (CZ), 13.05.2002-16.05.2002]
R&D Projects: GA ČR GP101/01/P039
Keywords : Hip joint endoprosthesis * measured inaccuraceis * modelling
Subject RIV: FS - Medical Facilities ; Equipment
Permanent Link: http://hdl.handle.net/11104/0107666 - 10.0212114 - UT-L 20020060 RIV PL cze C - Conference Paper (international conference)
Fuis, Vladimír
Výpočtové modelování napjatosti v keramické hlavici totální kyčelní endoprotézy.
[Computational modelling of the stress in the ceramic head of hip joint endoprosthesis.]
Zeszyty naukowe katedry mechaniki stosowanej. Gliwice: Politechnika Slaska, Wydzial mechaniczny technologiczny, Kat, 2002, s. 35-38. ISBN 83-917224-0-6.
[International seminar of Applied Mechanics /6./. Wisla (PL), 31.05.2002-02.06.2002]
R&D Projects: GA ČR GA101/01/0974; GA ČR GP101/01/P039
Keywords : Hip joint endoprosthesis * measured inaccuraceis * in vivo loading
Subject RIV: JH - Ceramics, Fire-Resistant Materials and Glass
Permanent Link: http://hdl.handle.net/11104/0107663