Number of the records: 1
Operation and performance of the ATLAS semiconductor tracker in LHC Run 2
- 1.
SYSNO ASEP 0565743 Document Type J - Journal Article R&D Document Type Journal Article Subsidiary J Článek ve WOS Title Operation and performance of the ATLAS semiconductor tracker in LHC Run 2 Author(s) Aad, G. (FR)
Abbott, B. (US)
Abbott, D.C. (US)
Chudoba, Jiří (FZU-D) RID, ORCID
Hejbal, Jiří (FZU-D) RID, ORCID
Hladík, Ondřej (FZU-D) ORCID
Jačka, Petr (FZU-D) ORCID
Kepka, Oldřich (FZU-D) RID, ORCID
Kroll, Jiří (FZU-D) ORCID
Kupčo, Alexander (FZU-D) RID, ORCID
Latoňová, Věra (FZU-D) ORCID
Lokajíček, Miloš (FZU-D) RID, ORCID
Lysák, Roman (FZU-D) RID, ORCID
Marčišovský, Michal (FZU-D) RID, ORCID
Mikeštíková, Marcela (FZU-D) RID, ORCID
Němeček, Stanislav (FZU-D) RID, ORCID
Penc, Ondřej (FZU-D) ORCID
Šícho, Petr (FZU-D) RID, ORCID
Staroba, Pavel (FZU-D) RID, ORCID
Svatoš, Michal (FZU-D) RID, ORCID
Taševský, Marek (FZU-D) RID, ORCIDNumber of authors 2902 Article number P01013 Source Title Journal of Instrumentation. - : Institute of Physics Publishing - ISSN 1748-0221
Roč. 17, č. 1 (2022)Number of pages 55 s. Language eng - English Country GB - United Kingdom Keywords ATLAS ; performance ; tracking detector Subject RIV BF - Elementary Particles and High Energy Physics OECD category Particles and field physics R&D Projects LM2018104 GA MŠMT - Ministry of Education, Youth and Sports (MEYS) Research Infrastructure e-INFRA CZ - 90140 - CESNET, zájmové sdružení právnických osob Method of publishing Open access Institutional support FZU-D - RVO:68378271 UT WOS 000766149300002 EID SCOPUS 85124139113 DOI 10.1088/1748-0221/17/01/P01013 Annotation The semiconductor tracker (SCT) is one of the tracking systems for charged particles in the ATLAS detector. It consists of 4088 silicon strip sensor modules. During Run 2 (2015–2018) the Large Hadron Collider delivered an integrated luminosity of 156 fb−1−1 to the ATLAS experiment at a centre-of-mass proton-proton collision energy of 13 TeV. The instantaneous luminosity and pile-up conditions were far in excess of those assumed in the original design of the SCT detector. Due to improvements to the data acquisition system, the SCT operated stably throughout Run 2. It was available for 99.9% of the integrated luminosity and achieved a data-quality efficiency of 99.85%. Detailed studies have been made of the leakage current in SCT modules and the evolution of the full depletion voltage, which are used to study the impact of radiation damage to the modules. Workplace Institute of Physics Contact Kristina Potocká, potocka@fzu.cz, Tel.: 220 318 579 Year of Publishing 2023 Electronic address https://hdl.handle.net/11104/0337253
Number of the records: 1