Recent improvement of the design of the ITER steady-state magnetic sensors

  1. 1.
    SYSNO ASEP0538555
    Document TypeJ - Journal Article
    R&D Document TypeJournal Article
    Subsidiary JČlánek ve WOS
    TitleRecent improvement of the design of the ITER steady-state magnetic sensors
    Author(s) Entler, Slavomír (UFP-V) ORCID
    Kocan, M. (FR)
    Ďuran, Ivan (UFP-V) RID, ORCID
    Vayakis, G. (FR)
    Lucca, G. (ES)
    Vigano, F. (IT)
    Cantu, P. (FR)
    Number of authors7
    Source TitleIEEE Transactions on Plasma Science. - : Institute of Electrical and Electronics Engineers - ISSN 0093-3813
    Roč. 46, č. 5 (2018), s. 1276-1280
    Number of pages5 s.
    Languageeng - English
    CountryUS - United States
    KeywordsCalibration ; Hall effect devices ; iter ; magnetic field measurement ; measurement errors
    Subject RIVBL - Plasma and Gas Discharge Physics
    OECD categoryFluids and plasma physics (including surface physics)
    Method of publishingLimited access
    Institutional supportUFP-V - RVO:61389021
    UT WOS000431521700031
    EID SCOPUS85041689749
    DOI10.1109/TPS.2018.2795243
    AnnotationA recent improvement of the design of the ITER outer vessel steady-state magnetic field sensors (OVSS) is presented. OVSS features a pair of Hall sensors with a sensing layer made of bismuth. Sixty OVSS will be installed on the ITER vacuum vessel outer skin to perform an absolute measurement of magnetic field. The bismuth Hall sensor measurement is temperature dependent, and the maximum allowed OVSS error of 4-mT limits the error of the measurement of the Hall sensor temperature by an on-board thermocouple to be less than 0.28 °C. This error consists of the temperature difference between the thermocouple and Hall sensors, thermocouple calibration error, and thermocouple measurement error. The improved design of the sensor housing reduces the temperature difference between the thermocouple and the Hall sensors bellow 0.04 °C. Procedures of the calibration prior installation and in situ calibration will allow calibrating the on-board thermocouple with the error less than 0.06 °C. The thermocouple measurement error limit was determined as 0.27 °C in which case OVSS meets the maximum allowed error.
    WorkplaceInstitute of Plasma Physics
    ContactVladimíra Kebza, kebza@ipp.cas.cz, Tel.: 266 052 975
    Year of Publishing2021