    TitlePitfalls in the analysis of volatile breath biomarkers: suggested solutions and SIFT-MS quantification of single metabolites
    Author(s) Smith, D. (GB)
    Španěl, Patrik (UFCH-W) RID, ORCID
    Source TitleJournal of Breath Research. - : Institute of Physics Publishing - ISSN 1752-7155
    Roč. 9, č. 2 (2015), 022001
    Number of pages11 s.
    Languageeng - English
    CountryGB - United Kingdom
    KeywordsSIFT-MS ; volatile biomarkers ; quantifications
    Subject RIVCF - Physical ; Theoretical Chemistry
    Institutional supportUFCH-W - RVO:61388955
    UT WOS000355656200002
    EID SCOPUS84930625565
    DOI10.1088/1752-7155/9/2/022001
    AnnotationThe experimental challenges presented by the analysis of trace volatile organic compounds (VOCs) in exhaled breath with the objective of identifying reliable biomarkers are brought into focus. It is stressed that positive identification and accurate quantification of the VOCs are imperative if they are to be considered as discreet biomarkers. Breath sampling procedures are discussed and it is suggested that for accurate quantification on-line real time sampling and analysis is desirable. Whilst recognizing such real time analysis is not always possible and sample collection is often required, objective recognition of the pitfalls involved in this is essential. It is also emphasized that mouth-exhaled breath is always contaminated to some degree by orally generated compounds and so, when possible, analysis of nose-exhaled breath should be performed. Some difficulties in breath analysis are mitigated by the choice of analytical instrumentation used, but no single instrument can provide solutions to all the analytical challenges. Analysis and interpretation of breath analysis data, however acquired, needs to be treated circumspectly. In particular, the excessive use of statistics to treat imperfect mass spectrometry/mobility spectra should be avoided, since it can result in unjustifiable conclusions. It is should be understood that recognition of combinations of VOCs in breath that, for example, apparently describe particular cancer states, will not be taken seriously until they are replicated in other laboratories and clinics. Finally, the inhibiting notion that single biomarkers of infection and disease will not be identified and utilized clinically should be dispelled by the exemplary and widely used single biomarkers NO and H-2 and now, as indicated by recent selected ion flow tube mass spectroscopy (SIFT-MS) results, triatomic hydrogen cyanide and perhaps pentane and acetic acid.
    WorkplaceJ. Heyrovsky Institute of Physical Chemistry
    ContactMichaela Knapová, michaela.knapova@jh-inst.cas.cz, Tel.: 266 053 196