Number of the records: 1  

Neutron diffraction measurements of residual stresses in a 50 mm thick weld

  1. 1.
    SYSNO ASEP0365521
    Document TypeJ - Journal Article
    R&D Document TypeJournal Article
    Subsidiary JČlánek ve WOS
    TitleNeutron diffraction measurements of residual stresses in a 50 mm thick weld
    Author(s) Woo, W. (KR)
    Em, V. (KR)
    Mikula, Pavol (UJF-V) RID, ORCID, SAI
    An, G.B. (KP)
    Seong, B. S. (KR)
    Number of authors5
    Source TitleMaterials Science and Engineering A Structural Materials Properties Microstructure and Processing. - : Elsevier - ISSN 0921-5093
    Roč. 528, č. 12 (2011), s. 4120-4124
    Number of pages5 s.
    Languageeng - English
    CountryCH - Switzerland
    KeywordsPLATE
    Subject RIVBM - Solid Matter Physics ; Magnetism
    R&D ProjectsKJB100480901 GA AV ČR - Academy of Sciences of the Czech Republic (AV ČR)
    CEZAV0Z10480505 - UJF-V (2005-2011)
    UT WOS000289389400025
    DOI10.1016/j.msea.2011.02.009
    AnnotationResidual stresses were determined through the thickness of a 50 mm thick ferrite steel weld plate using neutron diffraction. Whereas the limiting penetration depth for iron-based alloys is about 25 mm in the most typical neutron diffractometers, we significantly enhanced the penetration depth up to 50 mm with 2 mm spatial resolution by using the neutron wavelength of 2.39 angstrom. The selected wavelength minimizes the total neutron cross-section and beam attenuation, thereby, maximizes the neutron fluxes at depth.
    WorkplaceNuclear Physics Institute
    ContactMarkéta Sommerová, sommerova@ujf.cas.cz, Tel.: 266 173 228
    Year of Publishing2012