Number of the records: 1  

Comparison of low cycle fatigue of ductile cast irons with different matrix alloyed with nickel

  1. 1.
    SYSNO ASEP0355181
    Document TypeJ - Journal Article
    R&D Document TypeJournal Article
    Subsidiary JČlánek ve WOS
    TitleComparison of low cycle fatigue of ductile cast irons with different matrix alloyed with nickel
    Author(s) Petrenec, Martin (UFM-A)
    Tesařová, H. (CZ)
    Beran, Přemysl (UJF-V) RID, ORCID, SAI
    Šmíd, Miroslav (UFM-A) RID, ORCID
    Roupcová, Pavla (UFM-A) RID, ORCID
    Source TitleProcedia Engineering. - Amsterdam : Elsevier BV
    Roč. 2, č. 1 (2010), s. 2307-2316
    Number of pages10 s.
    ActionFatigue 2010
    Event date06.06.2010-11.06.2010
    VEvent locationPraha
    CountryCZ - Czech Republic
    Event typeWRD
    Languageeng - English
    CountryNL - Netherlands
    KeywordsLow cycle fatigue ; ferritic ductile cast iron ; ADI ; nickel alloying ; neutron diffraction
    Subject RIVJL - Materials Fatigue, Friction Mechanics
    R&D ProjectsGAP108/10/2371 GA ČR - Czech Science Foundation (CSF)
    CEZAV0Z20410507 - UFM-A (2005-2011)
    AV0Z10480505 - UJF-V (2005-2011)
    UT WOS000278762900245
    DOI10.1016/j.proeng.2010.03.247
    AnnotationTotal strain controlled tests have been performed on cylindrical specimens of austempered ductile cast iron (ADI) and ductile cast iron with the ferritic matrix, both alloyed with 2.75% Ni, with the aim to compare cyclic plasticity and the fatigue life at temperatures 23 °C and–45 °C.In ADI the measurement of retained austenite by neutron diffraction before and after fatigue tests is used to discuss the cyclic stress-strain response. Cyclic hardening/softening curves, cyclic stress-strain curves and fatigue life curves were obtained for both temperatures and materials. Cyclic stress-strain curve obtained at–45 °C is shifted to higher stress amplitudes relative to room temperature curve. The Manson-Coffin curves are identical for both materials and temperatures while the Basquin curve is shifted to longer fatigue life for ADI. The surface relief developed during fatigue was studied using SEM. Fatigue cracks initiated preferably from persistent slip markings at the interface of graphite nodule.
    WorkplaceInstitute of Physics of Materials
    ContactYvonna Šrámková, sramkova@ipm.cz, Tel.: 532 290 485
    Year of Publishing2011