Emissivity and in situ measurement of amount of water condensed on a metallic sample

  1. 1.
    SYSNO ASEP0352298
    Document TypeC - Proceedings Paper (int. conf.)
    R&D Document TypeConference Paper
    TitleEmissivity and in situ measurement of amount of water condensed on a metallic sample
    Author(s) Musilová, Věra (UPT-D) RID, SAI, ORCID
    Hanzelka, Pavel (UPT-D) RID, ORCID, SAI
    Králík, Tomáš (UPT-D) RID, ORCID, SAI
    Number of authors3
    Source TitleThe 11th Cryogenics 2010 - IIR International Conference. - Praha : ICARIS Ltd, 2010 - ISBN 978-2-913149-77-9
    Pagess. 37-42
    Number of pages6 s.
    ActionCryogenics 2010 /11./
    Event date26.04.2010-29.04.2010
    VEvent locationBratislava
    CountrySK - Slovakia
    Event typeWRD
    Languageeng - English
    CountryCZ - Czech Republic
    Keywordsradiant properties ; emissivity ; heat transfer ; cryostats ; water condensate
    Subject RIVBJ - Thermodynamics
    R&D ProjectsED0017/01/01 GA MŠMT - Ministry of Education, Youth and Sports (MEYS)
    IAA100650804 GA AV ČR - Academy of Sciences of the Czech Republic (AV ČR)
    CEZAV0Z20650511 - UPT-D (2005-2011)
    AnnotationThermal radiation emissivity of technically pure aluminium contaminated by water condensate was obtained by measurement of the heat transferred between two parallel surfaces, the surface of the aluminium sample and of a dielectric layer used as a reference “black surface”. In situ measured water amount was derived from the heat transferred by vapour of subliming water during ramp of the sample temperature from 5 K to 300 K.