Number of the records: 1
Controllable Thermoelastic Actuator with Mechanical Friction Clutches for Accurate Setting of Position
- 1.
SYSNO ASEP 0350989 Document Type J - Journal Article R&D Document Type Journal Article Subsidiary J Článek ve WOS Title Controllable Thermoelastic Actuator with Mechanical Friction Clutches for Accurate Setting of Position Author(s) Doležel, Ivo (UT-L) RID
Krónerová, E. (CZ)
Ulrych, B. (CZ)Source Title Przeglad Elektrotechniczny - ISSN 0033-2097
Roč. 86, č. 1 (2010), s. 77-79Number of pages 3 s. Publication form CD ROM - CD ROM Language eng - English Country PL - Poland Keywords thermoelastic effect ; electromagnetic field ; temperature field Subject RIV JA - Electronics ; Optoelectronics, Electrical Engineering R&D Projects GA102/09/1305 GA ČR - Czech Science Foundation (CSF) CEZ AV0Z20570509 - UE-C, UT-L (2005-2011) UT WOS 000273209400024 Annotation Accurate setting of position based on thermoelastic effect produced by induction heating is suggested. Its controllability is reached by supplementary friction clutches that hold the dilatation element in the required position. The paper presents the arrangement of the device, its mathematical model and way of its numerical solution. The operation properties of the device are illustrated on an example whose results are discussed. Workplace Institute of Thermomechanics Contact Marie Kajprová, kajprova@it.cas.cz, Tel.: 266 053 154 ; Jana Lahovská, jaja@it.cas.cz, Tel.: 266 053 823 Year of Publishing 2011
Number of the records: 1