Number of the records: 1
Interlock system for the COMPASS tokamak
- 1.
SYSNO ASEP 0349232 Document Type J - Journal Article R&D Document Type Journal Article Subsidiary J Článek ve WOS Title Interlock system for the COMPASS tokamak Author(s) Hron, Martin (UFP-V) RID, ORCID
Sova, J. (CZ)
Šíba, J. (CZ)
Kovář, J. (CZ)
Adámek, Jiří (UFP-V) RID, ORCID
Pánek, Radomír (UFP-V) RID
Havlíček, Josef (UFP-V) RID, ORCID
Písačka, Jan (UFP-V) RID
Mlynář, Jan (UFP-V) RID
Stöckel, Jan (UFP-V) RIDSource Title Fusion Engineering and Design. - : Elsevier - ISSN 0920-3796
Roč. 85, 3-4 (2010), s. 505-508Number of pages 4 s. Publication form web - web Action IAEA Technical Meeting on Control, Data Acquisition and Remote Participation for Fusion Research/7th./ Event date 15.06.2009-19.06.2009 VEvent location Aix – en – Provence Country FR - France Event type WRD Language eng - English Country CH - Switzerland Keywords Tokamak operation ; Interlock ; Personnel safety Subject RIV BL - Plasma and Gas Discharge Physics R&D Projects 7G09042 GA MŠMT - Ministry of Education, Youth and Sports (MEYS) GD202/08/H057 GA ČR - Czech Science Foundation (CSF) CEZ AV0Z20430508 - UFP-V (2005-2011) UT WOS 000281190000051 DOI 10.1016/j.fusengdes.2010.03.054 Annotation The COMPASS tokamak has started its operation recently at the Institute of Plasma Physics ASCRin Prague, Czech Republic. An important issue of the operation is the interlock system, which secures the safety of the personnel. The personnel protection is based on a restricted access into the experimental hall during the tokamak operation. An experimental hall access system, based on Honeywell WIN-PAKTM2005, allows to set the status of the experimental area and to control the movement of the personnel. A hardware interlock, based on a PLC connected on PESNET bus, interprets the experimental hall status and controls the safety of the operation of key systems accordingly. The permit for operation is granted and the real status of the systems is reported by hard-wired potential-less contacts. Visualization PC creates an operator interface, on which is running a .NET application; this PC is connected with PLC via PESNET bus. Details of the set-up are described in this contribution. Workplace Institute of Plasma Physics Contact Vladimíra Kebza, kebza@ipp.cas.cz, Tel.: 266 052 975 Year of Publishing 2011
Number of the records: 1