Number of the records: 1
Spectral Line Amplitudes of Thermally Polarized 129 Xenon in Comparison with Hyperpolarized 129 Xenon
- 1.
SYSNO ASEP 0336836 Document Type C - Proceedings Paper (int. conf.) R&D Document Type Conference Paper Title Spectral Line Amplitudes of Thermally Polarized 129 Xenon in Comparison with Hyperpolarized 129 Xenon Author(s) Rychnovský, Jan (UPT-D) RID, SAI
Buchta, Zdeněk (UPT-D) RID, SAI, ORCID
Bartušek, Karel (UPT-D) RID, ORCID, SAINumber of authors 3 Source Title AMTEE '09 - 9th International Conference on Advanced Methods in the Theory of Electrical Engineering. - Plzeň : University of West Bohemia, 2009 - ISBN 978-80-7043-821-3 Pages v1-2 Number of pages 2 s. Action AMTEE '09 - Advanced Methods in the Theory of Electrical Engineering /9./ Event date 07.09.2009-09.09.2009 VEvent location Cheb Country CZ - Czech Republic Event type EUR Language eng - English Country CZ - Czech Republic Keywords hyperpolarized ; xenon ; ECL laser ; spectral line amplitude enhancement Subject RIV BH - Optics, Masers, Lasers CEZ AV0Z20650511 - UPT-D (2005-2011) Annotation We present the experimental results of hyperpolarized 129Xe spectral line amplitude obtained by 4.7 T NMR system and high power semiconductor laser with reduced emission linewidth. The hyperpolarization process was based on the spin exchange collision technique between 129Xe atoms and optically pumped Rb atoms. The amplification of the 129Xe spectral line amplitude about 400 times was achieved. Furthermore, the influence of the optical pumping duration to the 129Xe spectral line amplitude was surveyed. Workplace Institute of Scientific Instruments Contact Martina Šillerová, sillerova@ISIBrno.Cz, Tel.: 541 514 178 Year of Publishing 2010