Air Ions Concentration Influence on Bacterial Colony Count in the Dwelling Spaces

  1. 1.
    SYSNO ASEP0336709
    Document TypeC - Proceedings Paper (int. conf.)
    R&D Document TypeConference Paper
    TitleAir Ions Concentration Influence on Bacterial Colony Count in the Dwelling Spaces
    Author(s) Szabó, Z. (CZ)
    Bartušek, Karel (UPT-D) RID, ORCID, SAI
    Number of authors2
    Source TitlePIERS 2009 Moscow: Progess in Electromagnetics Research Symposium - Proceedings. - Cambridge : Electromagnetics Academy, 2009 - ISSN 1559-9450 - ISBN 978-1-934142-10-3
    Pagess. 1110-1112
    Number of pages3 s.
    ActionProgress in Electromagnetics Research Symposium 2009 Moscow
    Event date18.08.2009-21.08.2009
    VEvent locationMoscow
    CountryRU - Russian Federation
    Event typeWRD
    Languageeng - English
    CountryUS - United States
    KeywordsAir Ions Concentration ; Bacterial Colony
    Subject RIVJA - Electronics ; Optoelectronics, Electrical Engineering
    R&D ProjectsGA102/09/0314 GA ČR - Czech Science Foundation (CSF)
    CEZAV0Z20650511 - UPT-D (2005-2011)
    AnnotationThe infuence of air ion concentration on the bacterial colony count in the living spaces was examined by means of guardian condenser and aeroscopic method. Experiment was realized at the Department of Theoretical and Experimental Electrical Engineering (DTEEE) in the Faraday cage room and in the common laboratory. The methodology and the technique of our measurement are described in this article. Some of our measurement results are presented. The relation between the measured bacterial colony count and the air ion concentration was evaluated. The conclusion is made on the basis of the relations which were found out.