Number of the records: 1
Lifetime study of unidirectional Nicalon - polysiloxane composites at elevated temperatures
- 1.
SYSNO ASEP 0207574 Document Type C - Proceedings Paper (int. conf.) R&D Document Type Conference Paper Title Lifetime study of unidirectional Nicalon - polysiloxane composites at elevated temperatures Author(s) Glogar, Petr (USMH-B) RID
Hvizdoš, P. (SK)
Kolář, František (USMH-B)
Rudnayová, E. (SK)Source Title Brittle Matrix Composites 6 / Brandt A. ; Li V.C. ; Marshall I.H.. - Warszawa : ZTUREK RSI and Woodhead Publishing, 2000 - ISBN 1-85573-551-2 Pages s. 557-565 Number of pages 9 s. Action Brittle Matrix Composites 6 Event date 09.10.2000-11.10.2000 VEvent location Warszawa Country PL - Poland Language eng - English Country PL - Poland Subject RIV JH - Ceramics, Fire-Resistant Materials and Glass R&D Projects GA104/00/1140 GA ČR - Czech Science Foundation (CSF) GA106/99/0096 GA ČR - Czech Science Foundation (CSF) CEZ AV0Z3046908 - USMH-B Annotation Nicalon - reinforced composites with ex-polymethylphenylsiloxane matrix were made by pyrolysis at 700 - 1000řC. The bending strength and work to fracture slightly decreased with increasing pyrolysis temperature 700 - 900řC but dropped for samples pyrolysed at 1000 C. The cumulative damage of almost all samples took place in the stress interval of 100 - 150 MPa. The lifetime tests showed a slight tendency of decreasing the stress resistance with increasing test temperature from 500řC to 600řC. Workplace Institute of Rock Structure and Mechanics Contact Iva Švihálková, svihalkova@irsm.cas.cz, Tel.: 266 009 216 Year of Publishing 2001