Number of the records: 1  

Qualification by HHF tests of W coatings on Inconel superalloy for COMPASS-U plasma-facing components

  1. 1.
    SYSNO ASEP0616718
    Document TypeJ - Journal Article
    R&D Document TypeJournal Article
    Subsidiary JČlánek ve WOS
    TitleQualification by HHF tests of W coatings on Inconel superalloy for COMPASS-U plasma-facing components
    Author(s) Dejarnac, Renaud (UFP-V) RID, ORCID
    Matějíček, Jiří (UFP-V) RID, ORCID
    Greuner, H. (DE)
    Böswirth, B. (DE)
    Gerardin, Jonathan (UFP-V) ORCID
    Kopeček, Jaromír (FZU-D) RID, ORCID
    Kirhetov, Daniil (UFP-V)
    Number of authors7
    Article number101841
    Source TitleNuclear Materials and Energy. - : Elsevier
    Roč. 42, March (2025)
    Number of pages15 s.
    Languageeng - English
    CountryNL - Netherlands
    KeywordsCOMPASS-U ; PFCs ; tungsten
    Subject RIVJG - Metallurgy
    OECD categoryMaterials engineering
    Subject RIV - cooperationInstitute of Physics - Nuclear, Atomic and Molecular Physics, Colliders
    R&D ProjectsLM2023045 GA MŠMT - Ministry of Education, Youth and Sports (MEYS)
    EF16_019/0000768 GA MŠMT - Ministry of Education, Youth and Sports (MEYS)
    Method of publishingOpen access
    Institutional supportUFP-V - RVO:61389021 ; FZU-D - RVO:68378271
    UT WOS001390782000001
    EID SCOPUS85212073162
    DOI https://doi.org/10.1016/j.nme.2024.101841
    AnnotationCoating Inconel tiles by tungsten is a necessary step towards the full tungsten first wall coverage of the COMPASS-U tokamak. Thin tungsten coatings on Inconel based on physical vapor deposition were successfully produced consequently to a programme of R&D within the COMPASS Upgrade project by three different suppliers. This contribution presents the qualification phase of these tungsten coatings under COMPASS-U relevant high heat fluxes (50 cycles at 10 MW/m2, 100 cycles at 30 MW/m2) in the neutral beam test facility GLADIS. The behavior of the different tungsten coatings during exposures and the main conclusions from the post-mortem analysis are presented. The most important result is that under COMPASS-U relevant heat fluxes, no damage was observed on the front face of all samples, proving the practicability of such coatings for fusion application.
    WorkplaceInstitute of Plasma Physics
    ContactVladimíra Kebza, kebza@ipp.cas.cz, Tel.: 266 052 975
    Year of Publishing2025
    Electronic addresshttps://www.sciencedirect.com/science/article/pii/S2352179124002643?via%3Dihub