Number of the records: 1
Voltammetric study of new psychoactive substance 3-fluorophenmetrazine
- 1.0557347 - ÚFCH JH 2024 RIV DE eng J - Journal Article
Jiroušková, Eliška - Čabala, R. - Sokolová, Romana
Voltammetric study of new psychoactive substance 3-fluorophenmetrazine.
Electrochemical Science Advances. Roč. 3, č. 5 (2023), č. článku e2100223. ISSN 2698-5977. E-ISSN 2698-5977
R&D Projects: GA ČR(CZ) GA19-03160S
Institutional support: RVO:61388955
Keywords : 3-fluorophenmetrazine * cyclic voltammetry * differential pulse voltammetry * HOMO/LUMOspatial distribution * IR spectroelectrochemistry
OECD category: Electrochemistry (dry cells, batteries, fuel cells, corrosion metals, electrolysis)
Impact factor: 2.9, year: 2023
Method of publishing: Open access
DOI: https://doi.org/10.1002/elsa.202100223
Electrochemical oxidation of the new psychoactive substance 3-fluorophenmetrazine (FPM) was studied in phosphate buffers by cyclic voltammetry and differential pulse voltammetry (DPV) on a glassy carbon electrode. The redox potential of FPM in buffered solution strongly depends on pH. Cyclic voltammetry behavior shows the partial influence of adsorption on the electrode process not allowing detailed analysis of the individual steps of the reaction scheme, it means the involvement of electron transfer (E) and chemical reaction (C). Nevertheless, the irreversible shape of the cyclic voltammogram is explained by the participation of hydroxylation nucleophilic addition of water (hydroxylation) after two-electron/two-proton oxidation of molecule at the tetrahydro-1,4-oxazine ring. The suggested mechanism leading to hydroxylated derivative 2-(3-fluorophenyl)-3-methyl-5-hydroxymorfolin is supported by the calculated highest occupied molecular orbital spatial distribution and atomic charges calculations for electrochemically formed radical cation. Infrared spectroelectrochemistry performed during oxidation in acetonitrile/water also supported the formation of this product.
The analytical method of FPM determination on glassy carbon electrode was developed using DPV with an attained limit of detection = 4.7 μmol/L in phosphate buffer of pH 9. The linear range of the calibration curve is from 7.0 to 107.00 μmol/L, correlation coefficient (r) = 0.9988.
Permanent Link: http://hdl.handle.net/11104/0331384
File Download Size Commentary Version Access 0557347.pdf 1 2.6 MB open access Publisher’s postprint open-access