Number of the records: 1  

Fabrication of monolithic capillary columns with inner diameter 50-530 mu m employing a mixture of pentaerythritol tetraacrylate and polyhedral oligomeric silsesquioxane-methacrylate as crosslinkers

  1. 1.
    SYSNO ASEP0556696
    Document TypeJ - Journal Article
    R&D Document TypeJournal Article
    Subsidiary JČlánek ve WOS
    TitleFabrication of monolithic capillary columns with inner diameter 50-530 mu m employing a mixture of pentaerythritol tetraacrylate and polyhedral oligomeric silsesquioxane-methacrylate as crosslinkers
    Author(s) Planeta, Josef (UIACH-O) RID, ORCID
    Moravcová, Dana (UIACH-O) RID, ORCID
    Karásek, Pavel (UIACH-O) RID, ORCID
    Roth, Michal (UIACH-O) RID, ORCID
    Number of authors4
    Source TitleJournal of Separation Science. - : Wiley - ISSN 1615-9306
    Roč. 45, č. 17 (2022), s. 3256-3263
    Number of pages8 s.
    Publication formPrint - P
    Languageeng - English
    CountryDE - Germany
    Keywordsliquid-chromatography ; inverse size-exclusion chromatography ; monoliths
    Subject RIVCB - Analytical Chemistry, Separation
    OECD categoryAnalytical chemistry
    Method of publishingLimited access
    Institutional supportUIACH-O - RVO:68081715
    UT WOS000779885000001
    EID SCOPUS85127682682
    DOI10.1002/jssc.202200176
    AnnotationHighly crosslinked monolithic capillary columns with inner diameters in the range of 50-530 mu m were prepared by radical polymerization of pentaerythritol tetraacrylate, polyhedral oligomeric silsesquioxane-methacrylate, and n-octadecyl methacrylate in the presence of methanol, dodecyl alcohol, and polyethylene glycol lauryl ether. Columns were evaluated by inverse size-exclusion chromatography employing a set of polystyrene standards of narrow molecular-size distribution and by scanning electron microscopy. Chromatographic performance under reversed-phase conditions was also evaluated. The combination of two effective crosslinkers as pentaerythritol tetraacrylate and polyhedral oligomeric silsesquioxane-methacrylate in the polymerization mixture allows for the preparation of robust and efficient monolithic capillary columns within a fairly wide range of internal diameters.
    WorkplaceInstitute of Analytical Chemistry
    ContactIveta Drobníková, drobnikova@iach.cz, Tel.: 532 290 234
    Year of Publishing2023
    Electronic addresshttp://hdl.handle.net/11104/0330816
Number of the records: 1  

  This site uses cookies to make them easier to browse. Learn more about how we use cookies.