A microfluidic device for monitoring cancer cell migration

  1. 1.
    0481945 - ÚIACH 2018 KR eng A - Abstract
    Ledvina, Vojtěch - Klepárník, Karel
    A microfluidic device for monitoring cancer cell migration.
    HPLC 2017 Jeju Program. 2017. s. 1-1.
    [HPLC 2017. International Symposium on High Performance Liquid Phase Separations and Related Techniques /46./. 05.11.2017-09.11.2017, Jeju]
    R&D Projects: GA ČR(CZ) GA17-01995S
    Institutional support: RVO:68081715
    Keywords : microfluidics * cancer * invasion
    Subject RIV: CB - Analytical Chemistry, Separation

    A PDMS based microfluidici device was developed for monitoring migration and invasion of cancer cells. The device consists of arrays of pillars with decreasing spacing size that mimic the narrow pores within tissues of human body.