Number of the records: 1  

The flow of mixture vapors in the athmospheric column, comparison of new distributor and new tray

  1. 1.
    0440251 - ÚGN 2015 RIV CZ eng V - Research Report
    Říha, Zdeněk
    The flow of mixture vapors in the athmospheric column, comparison of new distributor and new tray.
    Brno: GTC Technology Europe, s.r.o, 2014. 84 s.
    Institutional support: RVO:68145535
    Keywords : mixture vapors * CFD analysis * velocity density pressure
    Subject RIV: JQ - Machines ; Tools

    The description of CFD analysis and the description of mixture gas flow in the atmospheric column are listed in the report. This article builds on previous work [1]. There were calculated two cases with original distributor and with GT-OPTIFLOW distributor, see [1]. This article adds next two cases. The case with adjusted GT-OPTIFLOW distributor (enclosure 1) and adjusted GT-OPTIFLOW distributor with newly designed the chimney tray and new layout of the packing bed (enclosure 2). The flow area of the newly designed chimney tray is smaller than for previous design (5,36m2 vs. 6,89m2). New layout of the packing bed has smaller flow area (28,27m2 vs. 29,35m2) and higher pressure drop (129 Pa vs. 80Pa) in comparison with last design of the packing bed also used in [1].
    Permanent Link: http://hdl.handle.net/11104/0243380

     
     
Number of the records: 1  

  This site uses cookies to make them easier to browse. Learn more about how we use cookies.