Number of the records: 1  

Measuring human remains in the field: Grid technique, total station, or MicroScribe?

  1. 1.
    SYSNO ASEP0383800
    Document TypeJ - Journal Article
    R&D Document TypeJournal Article
    Subsidiary JČlánek ve WOS
    TitleMeasuring human remains in the field: Grid technique, total station, or MicroScribe?
    Author(s) Sládek, Vladimír (UBO-W) RID
    Galeta, P. (CZ)
    Sosna, D. (CZ)
    Number of authors3
    Source TitleForensic Science International. - : Elsevier - ISSN 0379-0738
    Roč. 221, 1-3 (2012), s. 16-22
    Number of pages7 s.
    Languageeng - English
    CountryIE - Ireland
    KeywordsExcavation ; Field anthropology ; Human skeleton ; Measuring error
    Subject RIVAC - Archeology, Anthropology, Ethnology
    Institutional supportUBO-W - RVO:68081766
    UT WOS000306967300013
    EID SCOPUS84864364823
    DOI10.1016/j.forsciint.2012.03.018
    AnnotationAlthough three-dimensional (3D) coordinates for human intra-skeletal landmarks are among the most important data that anthropologists have to record in the field, little is known about the reliability of various measuring techniques. We compared the reliability of three techniques used for 3D measurement of human remain in the field: grid technique (GT), total station (TS), and MicroScribe (MS). We measured 365 field osteometric points on 12 skeletal sequences excavated at the Late Medieval/Early Modern churchyard in Vs. eruby, Czech Republic. We compared intra-observer, inter-observer, and inter-technique variation using mean difference (MD), mean absolute difference (MAD), standard deviation of difference (SDD), and limits of agreement (LA). All three measuring techniques can be used when accepted error ranges can be measured in centimeters. When a range of accepted error measurable in millimeters is needed, MS offers the best solution. TS can achieve the same reliability as does MS, but only when the laser beam is accurately pointed into the center of the prism. When the prism is not accurately oriented, TS produces unreliable data. TS is more sensitive to initialization than is MS. GT measures human skeleton with acceptable reliability for general purposes but insufficiently when highly accurate skeletal data are needed. We observed high inter-technique variation, indicating that just one technique should be used when spatial data from one individual are recorded. Subadults are measured with slightly lower error than are adults. The effect of maximum excavated skeletal length has little practical significance in field recording. When MS is not available, we offer practical suggestions that can help to increase reliability when measuring human skeleton in the field.
    WorkplaceInstitute of Vertebrate Biology
    ContactHana Slabáková, slabakova@ivb.cz, Tel.: 543 422 524
    Year of Publishing2013
Number of the records: 1  

  This site uses cookies to make them easier to browse. Learn more about how we use cookies.