Male gender, Charnley class C, and severity of bone defects predict the risk for aseptic loosening in the cup of ABG I hip arthroplasty
- 1.0354722 - FZÚ 2011 RIV GB eng J - Journal Article
Gallo, J. - Havránek, Vítězslav - Zapletalová, J. - Lošťák, J.
Male gender, Charnley class C, and severity of bone defects predict the risk for aseptic loosening in the cup of ABG I hip arthroplasty.
BMC Musculoskeletal Disorders. Roč. 11, č. 10 (2010), 243/1-243/7. ISSN 1471-2474. E-ISSN 1471-2474
Institutional research plan: CEZ:AV0Z10100522
Keywords : hip arthroplasty * ABG I
Subject RIV: BH - Optics, Masers, Lasers
Impact factor: 1.941, year: 2010
We studied which factor could predict aseptic loosening in ABG I hip prosthesis with hydroxyapatite coating. Aseptic loosening and periprosthetic osteolysis are believed to be caused, at least in part, by increased polyethylene (PE) wear rate via particle disease. Based on it, increased PE wear rate should be associated with aseptic loosening regardless of the type of implant.