Number of the records: 1
Characteristics of edgeless silicon detectors for the Roman Pots of the TOTEM experiment at the LHC
- 1.0345246 - FZÚ 2011 RIV NL eng J - Journal Article
Ruggiero, G. - Avati, V. - Antchev, G. - Deile, M. - Eggert, K. - Eremin, V. - Kašpar, Jan - Niewiadomski, H. - Petajajarvi, J. - Radicioni, E. - Ravotti, F. - Radermacher, E. - Snoeys, W. - Spearman, W. - Wu, J.
Characteristics of edgeless silicon detectors for the Roman Pots of the TOTEM experiment at the LHC.
Nuclear Instruments & Methods in Physics Research Section A. Roč. 604, 1-2 (2009), s. 242-245. ISSN 0168-9002. E-ISSN 1872-9576.
[International Conference on Position Sensitive Detectors /8./. Glasgow, 01.09.2008-05.09.2008]
R&D Projects: GA MŠMT LA08015
Institutional research plan: CEZ:AV0Z10100502
Keywords : silicon edgeless detctors * radiation hardness
Subject RIV: BF - Elementary Particles and High Energy Physics
Impact factor: 1.317, year: 2009
TOTEM Roman Pot microstrip edgeless silicon detectors, fabrikated with standard planar technology, reach full sensitivity within 50 μm from the cut edge and can operate with high bias voltage at room temperature.
Permanent Link: http://hdl.handle.net/11104/0186562
Number of the records: 1