Number of the records: 1  

Robust Detection of Linear Part of Patlak-Rutland Plots

  1. 1.
    0321829 - ÚTIA 2009 CZ eng V - Research Report
    Šmídl, Václav
    Robust Detection of Linear Part of Patlak-Rutland Plots.
    [Detekce lineární části Patlak-Rutlandova grafu.]
    Praha: ÚTIA AV ČR, v.v.i, 2008. 11 s. Research Report, 2243.
    R&D Projects: GA MŠMT 1M0572
    Institutional research plan: CEZ:AV0Z10750506
    Keywords : Bayesian estimation * EM algorithm * graph fitting
    Subject RIV: BB - Applied Statistics, Operational Research
    http://library.utia.cas.cz/separaty/2008/AS/smidl-robust detection of linear part of patlak-rutland plots.pdf

    Detection of linear part of a graph is a common problem in data analysis. Specifically for the Patlak-Rutland plot, this step is an important part of functional analysis of renal activity. An automated method for detection is proposed and tested on 16 data sets of real medical data.

    Detekce lineární části grafu je častým problémem při analýze dat. Konkrétně pro Patlak-Rutlandův graf je daný úkol důležitý pro správné vyhodnocení funkce ledvin ze scintigrafického vyšetření. Automatická metoda detekce byla navržena a testována na šestnácti sadách reálných medicínských dat.
    Permanent Link: http://hdl.handle.net/11104/0170256

     
    FileDownloadSizeCommentaryVersionAccess
    0321829.pdf0213.5 KBOtheropen-access
     
Number of the records: 1  