Number of the records: 1  

Correlation of trabecular bone mechanical properties to its microstructure using μct-based FE modeling

  1. 1.
    0308076 - ÚTAM 2008 RIV CZ eng C - Conference Paper (international conference)
    Jiroušek, Ondřej - Vavřík, Daniel - Jakubek, J. - Dammer, J.
    Correlation of trabecular bone mechanical properties to its microstructure using μct-based FE modeling.
    [Korelace mechanických vlastností trabekulární kosti a její mikrostruktury za použití micko-CT a nanoindentace.]
    Engineering Mechanics 2008. Prague: Institute of Thermomechanics AS CR, v. v. i., 2008 - (Fuis, V.; Pásek, M.), s. 110-111. ISBN 978-80-87012-11-6.
    [Engineeering mechanics 2008. Svratka (CZ), 12.05.2008-15.05.2008]
    R&D Projects: GA ČR(CZ) GP103/07/P483
    Institutional research plan: CEZ:AV0Z20710524
    Keywords : trabecular bone * mikro-CT * finite element method
    Subject RIV: JJ - Other Materials

    For the investigation of trabecular bone microstructure and its relation to bone failure a combined approach utilizing FE models of the microstructure and compressive tests of small cylindrical samples is presented.

    V práci je prezentován kombinovaný přístup pro studium mechanických vlastností trabekulární kosti využívající MKP modely vnitřní struktury získaných prostřednictvím mikro-CT, který je porovnán s výsledky mechanických zkoušek na malých vzorcích.
    Permanent Link: http://hdl.handle.net/11104/0160661


     
     